Objective: We explored how a novel T1-weighted 3-dimensional (3D) fast spin echo (FSE) sequence (Cube; GE, Waukesha, Wis) might outperform conventional 2-dimensional (2D) FSE techniques for contrast-enhanced imaging of the pituitary and parasellar region.
Methods: Ninety-one patients were imaged with 3D Cube and conventional 2D FSE on a 3.0-T magnetic resonance scanner. Two neuroradiologists independently assessed images for anatomical delineation (infundibulum, optic apparatus, and cavernous sinus), degree of artifact, and confidence in lesion definition or exclusion using a 5-point scale. In addition, the readers were asked to rank overall preference.
Results: Readers A and B found 3D Cube to be better or equal to 2D FSE in 84% and 86% of the cases. Three-dimensional Cube provided significantly better images than 2D FSE with respect to delineation of the infundibulum (P < 0.0001), cavernous sinus (P < 0.0001), optic apparatus (P = 0.002 for reader A and P = 0.265 for reader B), and fewer artifacts at the sellar floor (P < 0.0001). Three-dimensional Cube provided greater lesion conspicuity or confidence in lesion exclusion (P < 0.0001).
Conclusions: Three-dimensional Cube provides superior quality with thinner slices as well as diminished artifact and can replace conventional 2D FSE sequences for routine evaluations of the pituitary and parasellar region.