Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events
- PMID: 26061125
- DOI: 10.1001/jamasurg.2015.0301
Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events
Abstract
Importance: Serious, preventable surgical events, termed never events, continue to occur despite considerable patient safety efforts.
Objective: To examine the incidence and root causes of and interventions to prevent wrong-site surgery, retained surgical items, and surgical fires in the era after the implementation of the Universal Protocol in 2004.
Data sources: We searched 9 electronic databases for entries from 2004 through June 30, 2014, screened references, and consulted experts.
Study selection: Two independent reviewers identified relevant publications in June 2014.
Data extraction and synthesis: One reviewer used a standardized form to extract data and a second reviewer checked the data. Strength of evidence was established by the review team. Data extraction was completed in January 2015.
Main outcomes and measures: Incidence of wrong-site surgery, retained surgical items, and surgical fires.
Results: We found 138 empirical studies that met our inclusion criteria. Incidence estimates for wrong-site surgery in US settings varied by data source and procedure (median estimate, 0.09 events per 10,000 surgical procedures). The median estimate for retained surgical items was 1.32 events per 10,000 procedures, but estimates varied by item and procedure. The per-procedure surgical fire incidence is unknown. A frequently reported root cause was inadequate communication. Methodologic challenges associated with investigating changes in rare events limit the conclusions of 78 intervention evaluations. Limited evidence supported the Universal Protocol (5 studies), education (4 studies), and team training (4 studies) interventions to prevent wrong-site surgery. Limited evidence exists to prevent retained surgical items by using data-matrix-coded sponge-counting systems (5 pertinent studies). Evidence for preventing surgical fires was insufficient, and intervention effects were not estimable.
Conclusions and relevance: Current estimates for wrong-site surgery and retained surgical items are 1 event per 100,000 and 1 event per 10,000 procedures, respectively, but the precision is uncertain, and the per-procedure prevalence of surgical fires is not known. Root-cause analyses suggest the need for improved communication. Despite promising approaches and global Universal Protocol evaluations, empirical evidence for interventions is limited.
Comment in
-
Emotional Aspects of Never Events.JAMA Surg. 2016 Jan;151(1):95. doi: 10.1001/jamasurg.2015.3085. JAMA Surg. 2016. PMID: 26422445 No abstract available.
-
Challenges in Reducing Surgical "Never Events".JAMA. 2015 Oct 6;314(13):1386-7. doi: 10.1001/jama.2015.12327. JAMA. 2015. PMID: 26441183 No abstract available.
Similar articles
-
Thinking in three's: changing surgical patient safety practices in the complex modern operating room.World J Gastroenterol. 2012 Dec 14;18(46):6712-9. doi: 10.3748/wjg.v18.i46.6712. World J Gastroenterol. 2012. PMID: 23239908 Free PMC article.
-
Prevention of Wrong Site Surgery, Retained Surgical Items, and Surgical Fires: A Systematic Review [Internet].Washington (DC): Department of Veterans Affairs (US); 2013 Sep. Washington (DC): Department of Veterans Affairs (US); 2013 Sep. PMID: 26225411 Free Books & Documents. Review.
-
Errors upstream and downstream to the Universal Protocol associated with wrong surgery events in the Veterans Health Administration.Am J Surg. 2015 Jul;210(1):6-13. doi: 10.1016/j.amjsurg.2014.10.030. Epub 2015 Mar 21. Am J Surg. 2015. PMID: 25873162
-
The Economics of Patient Surgical Safety.Surg Clin North Am. 2021 Feb;101(1):135-148. doi: 10.1016/j.suc.2020.09.005. Epub 2020 Nov 2. Surg Clin North Am. 2021. PMID: 33212074 Review.
-
Rates of Serious Surgical Errors in California and Plans to Prevent Recurrence.JAMA Netw Open. 2021 May 3;4(5):e217058. doi: 10.1001/jamanetworkopen.2021.7058. JAMA Netw Open. 2021. PMID: 33938938 Free PMC article.
Cited by
-
Unintended Souvenirs: Case Report of a Retained Foreign Body During Cosmetic Surgery Tourism.Aesthet Surg J Open Forum. 2024 Aug 29;6:ojae070. doi: 10.1093/asjof/ojae070. eCollection 2024. Aesthet Surg J Open Forum. 2024. PMID: 39421580 Free PMC article.
-
Unraveling the Enigma of Gossypiboma: A Series of 14 Cases Highlighting the Prevalence, Root Causes, and Outcomes in Resource-Limited Settings.Cureus. 2024 Jul 4;16(7):e63856. doi: 10.7759/cureus.63856. eCollection 2024 Jul. Cureus. 2024. PMID: 39100026 Free PMC article.
-
Raney clip left behind the titanium mesh after cranial surgery: Case report.Medicine (Baltimore). 2024 Jul 26;103(30):e39077. doi: 10.1097/MD.0000000000039077. Medicine (Baltimore). 2024. PMID: 39058869 Free PMC article.
-
Artificial intelligence model for automated surgical instrument detection and counting: an experimental proof-of-concept study.Patient Saf Surg. 2024 Jul 21;18(1):24. doi: 10.1186/s13037-024-00406-y. Patient Saf Surg. 2024. PMID: 39034409 Free PMC article.
-
Call me Ishmael: addressing the white whale of team communication in the operating room with labelled surgical caps at an academic medical centre.BMJ Open Qual. 2024 Apr 8;13(2):e002453. doi: 10.1136/bmjoq-2023-002453. BMJ Open Qual. 2024. PMID: 38589054 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous