Optimizing Hybrid Occlusion in Face-Jaw-Teeth Transplantation: A Preliminary Assessment of Real-Time Cephalometry as Part of the Computer-Assisted Planning and Execution Workstation for Craniomaxillofacial Surgery

Plast Reconstr Surg. 2015 Aug;136(2):350-362. doi: 10.1097/PRS.0000000000001455.

Abstract

Background: The aesthetic and functional outcomes surrounding Le Fort-based, face-jaw-teeth transplantation have been suboptimal, often leading to posttransplant class II/III skeletal profiles, palatal defects, and "hybrid malocclusion." Therefore, a novel technology-real-time cephalometry-was developed to provide the surgical team instantaneous, intraoperative knowledge of three-dimensional dentoskeletal parameters.

Methods: Mock face-jaw-teeth transplantation operations were performed on plastic and cadaveric human donor/recipient pairs (n = 2). Preoperatively, cephalometric landmarks were identified on donor/recipient skeletons using segmented computed tomographic scans. The computer-assisted planning and execution workstation tracked the position of the donor face-jaw-teeth segment in real time during the placement/inset onto recipient, reporting pertinent hybrid cephalometric parameters from any movement of donor tissue. The intraoperative data measured through real-time cephalometry were compared to posttransplant measurements for accuracy assessment. In addition, posttransplant cephalometric relationships were compared to planned outcomes to determine face-jaw-teeth transplantation success.

Results: Compared with postoperative data, the real-time cephalometry-calculated intraoperative measurement errors were 1.37 ± 1.11 mm and 0.45 ± 0.28 degrees for the plastic skull and 2.99 ± 2.24 mm and 2.63 ± 1.33 degrees for the human cadaver experiments. These results were comparable to the posttransplant relations to planned outcome (human cadaver experiment, 1.39 ± 1.81 mm and 2.18 ± 1.88 degrees; plastic skull experiment, 1.06 ± 0.63 mm and 0.53 ± 0.39 degrees).

Conclusion: Based on this preliminary testing, real-time cephalometry may be a valuable adjunct for adjusting and measuring "hybrid occlusion" in face-jaw-teeth transplantation and other orthognathic surgical procedures.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Aged, 80 and over
  • Anatomic Landmarks
  • Cadaver
  • Cephalometry / methods*
  • Craniofacial Abnormalities / diagnosis
  • Craniofacial Abnormalities / surgery*
  • Diagnosis, Computer-Assisted / methods*
  • Face / abnormalities
  • Face / surgery
  • Facial Transplantation / methods*
  • Female
  • Humans
  • Imaging, Three-Dimensional / methods
  • Jaw Abnormalities / surgery
  • Oral Surgical Procedures / methods
  • Orthognathic Surgical Procedures / methods
  • Sensitivity and Specificity
  • Surgery, Computer-Assisted / methods*
  • Tooth Abnormalities / surgery