[Determination and Emission of Condensable Particulate Matter from Coal-fired Power Plants]

Huan Jing Ke Xue. 2015 May;36(5):1544-9.
[Article in Chinese]

Abstract

The sampling-analysis method for CPM of stationary source was established and the sampling device was developed. The determination method was compared with EPA method 202 and applied in real-world test in coal-fired power plants. The result showed the average CPM emission concentration in the coal-fired power plant was (21.2 ± 3.5) mg · m(-3) while the FPM was (20.6 ± 10.0) mg · m(-3) during the same sampling period according to the method in the national standard. The high-efficiency dust removal device could efficiently reduce FPM emission but showed insignificant effect on CPM. The mass contribution of CPM to TPM would rise after high-efficiency dust removal rebuilding project, to which more attention should be paid. The condensate contributed 68% to CPM mass while the filter contributed 32%, and the organic component contributed little to CPM, accounting for only 1%.

MeSH terms

  • Air Pollutants / analysis*
  • Coal*
  • Dust
  • Particulate Matter / analysis*
  • Power Plants*

Substances

  • Air Pollutants
  • Coal
  • Dust
  • Particulate Matter