Electrophysiology Catheter Detection and Reconstruction From Two Views in Fluoroscopic Images
- PMID: 26441411
- DOI: 10.1109/TMI.2015.2482539
Electrophysiology Catheter Detection and Reconstruction From Two Views in Fluoroscopic Images
Abstract
Electrophysiology (EP) studies and catheter ablation have become important treatment options for several types of cardiac arrhythmias. We present a novel image-based approach for automatic detection and 3-D reconstruction of EP catheters where the physician marks the catheter to be reconstructed by a single click in each image. The result can be used to provide 3-D information for enhanced navigation throughout EP procedures. Our approach involves two X-ray projections acquired from different angles, and it is based on two steps: First, we detect the catheter in each view after manual initialization using a graph-search method. Then, the detection results are used to reconstruct a full 3-D model of the catheter based on automatically determined point pairs for triangulation. An evaluation on 176 different clinical fluoroscopic images yielded a detection rate of 83.4%. For measuring the error, we used the coupling distance which is a more accurate quality measure than the average point-wise distance to a reference. For successful outcomes, the 2-D detection error was 1.7 mm ±1.2 mm. Using successfully detected catheters for reconstruction, we obtained a reconstruction error of 1.8 mm ±1.1 mm on phantom data. On clinical data, our method yielded a reconstruction error of 2.2 mm ±2.2 mm.
Similar articles
-
Semi-automatic catheter reconstruction from two views.Med Image Comput Comput Assist Interv. 2012;15(Pt 2):584-91. doi: 10.1007/978-3-642-33418-4_72. Med Image Comput Comput Assist Interv. 2012. PMID: 23286096
-
Respiratory motion compensation by model-based catheter tracking during EP procedures.Med Image Anal. 2010 Oct;14(5):695-706. doi: 10.1016/j.media.2010.05.006. Epub 2010 Jun 10. Med Image Anal. 2010. PMID: 20579931
-
Toward multiple catheters detection in fluoroscopic image guided interventions.IEEE Trans Inf Technol Biomed. 2012 Jul;16(4):770-81. doi: 10.1109/TITB.2012.2189407. Epub 2012 Feb 28. IEEE Trans Inf Technol Biomed. 2012. PMID: 22389155
-
Robotic navigation and ablation.Minerva Cardioangiol. 2010 Dec;58(6):691-9. Minerva Cardioangiol. 2010. PMID: 21135809 Review.
-
Constrained stochastic state estimation of deformable 1D objects: Application to single-view 3D reconstruction of catheters with radio-opaque markers.Comput Med Imaging Graph. 2020 Apr;81:101702. doi: 10.1016/j.compmedimag.2020.101702. Epub 2020 Feb 7. Comput Med Imaging Graph. 2020. PMID: 32193055 Review.
Cited by
-
Shape Reconstruction Processes for Interventional Application Devices: State of the Art, Progress, and Future Directions.Front Robot AI. 2021 Nov 19;8:758411. doi: 10.3389/frobt.2021.758411. eCollection 2021. Front Robot AI. 2021. PMID: 34869615 Free PMC article. Review.
-
Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair.Int J Comput Assist Radiol Surg. 2018 Aug;13(8):1221-1231. doi: 10.1007/s11548-018-1779-6. Epub 2018 May 19. Int J Comput Assist Radiol Surg. 2018. PMID: 29779153
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources