Purpose: To create normative data in children from binocular multifocal ERG (mfERG) recordings and compare results with the macular thickness.
Methods: Forty-nine 5- to 15-year-old healthy, full-term children were examined with Espion Multifocal System, using DTL electrodes. The stimulus matrix consisted of 37 hexagonal elements. Amplitudes, implicit times and response densities (presented in three rings) of the first-order component P1 were analyzed. Measurements of macular thickness were performed with spectral-domain Cirrus OCT.
Results: There were no significant differences between right and left eyes regarding mfERG recordings. Median P1 implicit times of Rings 1-3 of the 46 right eyes were 30.0, 30.0 and 30.8 ms and response densities 20.5, 10.9 and 7.6 nV/deg(2), respectively. Implicit time was longer in boys than in girls (p = 0.009, 0.039, 0.005 in Rings 1-3) and was correlated with age (r s = 0.417, 0.316, 0.274 in Rings 1-3). Implicit time in Ring 1 correlated significantly with the inner circle of the OCT measurements (p = 0.014).
Conclusion: Binocular mfERG with DTL electrodes is a reliable test of the central macular function in children and correlates with macular structure. As previously not shown, there was a significant difference in implicit time between boys and girls.
Keywords: Binocular; DTL electrodes; Healthy children; Multifocal electroretinogram; Optic coherence tomography.