Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST)
- PMID: 26554611
- DOI: 10.3109/02713683.2015.1082185
Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST)
Abstract
Purpose: To evaluate theoretical biomechanical advantages of human corneas treated with small incision lenticule extraction (SMILE) compared with femtosecond laser-assisted LASIK (FS-LASIK) Patients and methods: In a prospective, comparative, non-randomized, consecutive case series patients with moderate to high myopia and/or astigmatism underwent corneal refractive surgery. Patients either received standard FS-LASIK or SMILE. Preoperatively and up to 3 months postoperatively data were analyzed including tomography with Pentacam HR, Goldmann tonometry, non-contact tonometry, and deformability of the cornea using an ultra-high-speed camera (Corvis ST). Data were analyzed and p < 0.05 was considered as statistically significant (t-test).
Results: Seventy-three patients (128 eyes) were treated. Forty-eight eyes of 29 patients underwent FS-LASIK and 80 eyes of 44 patients underwent SMILE. Preoperative spherical equivalent (SE) was -3.23 ± 1.64 D (FS-LASIK group) and -4.83 ± 1.63 D (SMILE group) (p < 0.0001). Almost all parameters obtained by Corvis ST between preoperative and postoperative measurements showed significant changes after refractive surgery. Significant changes were seen between both groups postoperatively. However, matched pair subgroup analysis (n = 69; 26 eyes FS-LASIK; 43 eyes SMILE) of eyes with initially equal pachymetry, intraocular pressure, SE, and difference of pre- to postoperative pachymetry (p>0.05), showed no significant changes in parameters measured with Corvis ST (p>0.05).
Conclusions: Corneal biomechanical parameters measured preoperatively with Corvis ST showed significant differences postoperatively in total and in both groups. In subgroup analysis with homogenous groups, FS-LASIK showed no significant changes in biomechanical data measured with Corvis ST compared with SMILE.
Keywords: Corneal biomechanics; Corvis ST; LASIK; SMILE.
Similar articles
-
Comparison of Corneal Biomechanics Treated With Femtosecond Laser-Assisted In Situ Keratomileusis and Small-Incision Lenticule Extraction by New Corneal Biomechanical Parameters of Corvis ST II.Cornea. 2023 Nov 1;42(11):1384-1390. doi: 10.1097/ICO.0000000000003191. Epub 2022 Dec 12. Cornea. 2023. PMID: 36729642 Clinical Trial.
-
Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK.Invest Ophthalmol Vis Sci. 2016 Aug 1;57(10):4180-6. doi: 10.1167/iovs.16-19615. Invest Ophthalmol Vis Sci. 2016. PMID: 27548888
-
Comparison Between Q-Adjusted LASIK and Small-Incision Lenticule Extraction for Correction of Myopia and Myopic Astigmatism.Eye Contact Lens. 2018 Nov;44 Suppl 2:S426-S432. doi: 10.1097/ICL.0000000000000532. Eye Contact Lens. 2018. PMID: 30024453
-
Central corneal sensitivity after small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a meta-analysis of comparative studies.BMC Ophthalmol. 2015 Oct 24;15:141. doi: 10.1186/s12886-015-0129-5. BMC Ophthalmol. 2015. PMID: 26499875 Free PMC article. Review.
-
Dry Eye After Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK: Meta-Analysis.Cornea. 2017 Jan;36(1):85-91. doi: 10.1097/ICO.0000000000000999. Cornea. 2017. PMID: 27560032 Review.
Cited by
-
Biomechanical Responses of Different Cap Thicknesses of Corneas After Small Incision Lenticule Extraction: Finite Element Analysis.Transl Vis Sci Technol. 2023 Apr 3;12(4):5. doi: 10.1167/tvst.12.4.5. Transl Vis Sci Technol. 2023. PMID: 37017958 Free PMC article.
-
Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study.Transl Vis Sci Technol. 2023 Mar 1;12(3):12. doi: 10.1167/tvst.12.3.12. Transl Vis Sci Technol. 2023. PMID: 36928130 Free PMC article.
-
Clinical Evaluation of Corneal Biomechanics following Laser Refractive Surgery in Myopic Eyes: A Review of the Literature.J Clin Med. 2022 Dec 28;12(1):243. doi: 10.3390/jcm12010243. J Clin Med. 2022. PMID: 36615041 Free PMC article. Review.
-
In Vivo Evaluation of the Effects of SMILE with Different Amounts of Stromal Ablation on Corneal Biomechanics by Optical Coherence Elastography.Diagnostics (Basel). 2022 Dec 22;13(1):30. doi: 10.3390/diagnostics13010030. Diagnostics (Basel). 2022. PMID: 36611322 Free PMC article.
-
Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery.BMC Ophthalmol. 2022 Oct 10;22(1):404. doi: 10.1186/s12886-022-02620-7. BMC Ophthalmol. 2022. PMID: 36217120 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
