Solid phase immunoassays (SPI) are now routinely used to detect HLA antibodies. However, the flow cytometric crossmatch (FCXM) remains the established method for assessing final donor-recipient compatibility. Since 2005 we have followed a protocol whereby the final allocation decision for renal transplantation is based on SPI (not the FCXM). Here we report long-term graft outcomes for 508 consecutive kidney transplants using this protocol. All recipients were negative for donor-specific antibody by SPI. Primary outcomes are graft survival and incidence of acute rejection within 1 year (AR <1 year) for FCXM+ (n = 54) and FCXM- (n = 454) recipients. Median follow-up is 7.1 years. FCXM+ recipients were significantly different from FCXM- recipients for the following risk factors: living donor (24% vs. 39%, p = 0.03), duration of dialysis (31.0 months vs. 13.5 months, p = 0.008), retransplants (17% vs. 7.3%, p = 0.04), % sensitized (63% vs. 19%, p = 0.001), and PRA >80% (20% vs. 4.8%, p = 0.001). Despite these differences, 5-year actual graft survival rates are 87% and 84%, respectively. AR <1 year occurred in 13% FCXM+ and 12% FCXM- recipients. Crossmatch status was not associated with graft outcomes in any univariate or multivariate model. Renal transplantation can be performed successfully, using SPI as the definitive test for donor-recipient compatibility.
© Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.