Background: Cardiac multidetector computed tomography (MDCT) has been mainly applied in the diagnosis of valvular heart morphology and function along with the assessment of coronary artery disease. This study aimed to evaluate the diagnostic performance of coronary MDCT angiography for the diagnosis of mitral valve prolapse (MVP), as compared to transthoracic echocardiography (TTE).
Materials and methods: A total of 40 patients who had undergone both TTE and MDCT within a three-month period were included in the study. Two parameters of mitral valve leaflet thickness and leaflet billowing were measured using both techniques. The MDCT results were compared with those of TTE, which was the reference standard.
Results: Implementing the Receiver Operating Characteristic (ROC) test on the data for MDCT-measured leaflet billowing received from MDCT angiography suggests that the area under the ROC curve is 96% for a declared variable, which is absolutely significant (P < 0.001), and MDCT-measured leaflet billowing is an appropriate index for the diagnosis of mitral valve prolapse. On the basis of the achieved cut-off point from the ROC analysis (which equals 2.5 mm leaftlet billowing) the MDCT-measured leaflet billowing takes a sensitivity and specificity of 68.4 and 95.2%. The false positive and false negative results are 4.8 and 31.6%. The positive and negative predictive values (PPV and NPV) of the revealed test indicate 92.9 and 76.9%, respectively. Finally, the consistency of the MDCT measured leaflet billowing for diagnosing the mitral valve prolapse is 82.5%. Based on the mentioned test, the consistency of the MDCT-measured leaflet thickness test is 47.5%.
Conclusion: Along with the assessment of coronary arteries, the presence or absence of MVP can be reliably evaluated by MDCT angiography.
Keywords: Computed tomography; MDCT angiography; echocardiography; mitral valve prolapse.