Lung anatomy, energy load, and ventilator-induced lung injury

Intensive Care Med Exp. 2015 Dec;3(1):34. doi: 10.1186/s40635-015-0070-1. Epub 2015 Dec 15.

Abstract

Background: High tidal volume can cause ventilator-induced lung injury (VILI), but positive end-expiratory pressure (PEEP) is thought to be protective. We aimed to find the volumetric VILI threshold and see whether PEEP is protective per se or indirectly.

Methods: In 76 pigs (22 ± 2 kg), we examined the lower and upper limits (30.9-59.7 mL/kg) of inspiratory capacity by computed tomography (CT) scan at 45 cmH2O pressure. The pigs underwent a 54-h mechanical ventilation with a global strain ((tidal volume (dynamic) + PEEP volume (static))/functional residual capacity) from 0.45 to 5.56. The dynamic strain ranged from 18 to 100 % of global strain. Twenty-nine pigs were ventilated with end-inspiratory volumes below the lower limit of inspiratory capacity (group "Below"), 38 within (group "Within"), and 9 above (group "Above"). VILI was defined as death and/or increased lung weight.

Results: "Below" pigs did not develop VILI; "Within" pigs developed lung edema, and 52 % died before the end of the experiment. The amount of edema was significantly related to dynamic strain (edema 188-153 × dynamic strain, R (2) = 0.48, p < 0.0001). In the "Above" group, 66 % of the pigs rapidly died but lung weight did not increase significantly. In pigs ventilated with similar tidal volume adding PEEP significantly increased mortality.

Conclusions: The threshold for VILI is the lower limit of inspiratory capacity. Below this threshold, VILI does not occur. Within these limits, severe/lethal VILI occurs depending on the dynamic component. Above inspiratory capacity stress at rupture may occur. In healthy lungs, PEEP is protective only if associated with a reduced tidal volume; otherwise, it has no effect or is harmful.

Keywords: Energy load; Experimental animal model; Inspiratory capacity; Lung stress and strain; Mechanical ventilation; Ventilator-induced lung injury.