Spectrum of false positivity for the fourth generation human immunodeficiency virus diagnostic tests

AIDS Res Ther. 2016 Jan 5:13:1. doi: 10.1186/s12981-015-0086-3. eCollection 2016.

Abstract

Novel fourth generation screening and confirmatory human immunodeficiency virus (HIV) assays are now commercially available and incorporated into new diagnostic algorithms. We report two cases involving a total of three patients which highlight the spectrum of false positivity for both the Abbott Architect p24 antigen/antibody assay and the confirmatory Multispot antibody differentiation test. We then discuss the mechanisms for false positivity and the associated clinical conditions or laboratory scenarios that may predispose to inaccurate interpretation.

Keywords: False positive; Fourth generation assays; HIV.

Publication types

  • Case Reports

MeSH terms

  • AIDS Serodiagnosis* / standards
  • Adult
  • False Positive Reactions
  • Female
  • HIV Infections / diagnosis*
  • Humans
  • Male
  • Middle Aged