Objectives: Steam sterilization in hospitals is an energy and water intensive process. Our aim was to identify opportunities to improve electricity and water use. The objectives were to find: the time sterilizers spent active, idle and off; the variability in sterilizer use with the time of day and day of the week; and opportunities to switch off sterilizers instead of idling when no loads were waiting, and the resultant electricity and water savings.
Methods: Analyses of routine data for one year of the activity of the four steam sterilizers in one hospital in Melbourne, Australia. We examined active sterilizer cycles, routine sterilizer switch-offs, and when sterilizers were active, idle and off. Several switch-off strategies were examined to identify electricity and water savings: switch off idle sterilizers when no loads are waiting and switch off one sterilizer after 10:00 h and a second sterilizer after midnight on all days.
Results: Sterilizers were active for 13,430 (38%) sterilizer-hours, off for 4822 (14%) sterilizer-hours, and idle for 16,788 (48%) sterilizer-hours. All four sterilizers were simultaneously active 9% of the time, and two or more sterilizers were idle for 69% of the time. A sterilizer was idle for two hours or less 13% of the time and idle for more than 2 h 87% of the time. A strategy to switch off idle sterilizers would reduce electricity use by 66 MWh and water use by 1004 kl per year, saving 26% electricity use and 13% of water use, resulting in financial savings of AUD$13,867 (UK£6,517) and a reduction in 79 tonnes of CO2 emissions per year. An alternative switch-off strategy of one sterilizer from 10:00 h onwards and a second from midnight would have saved 30 MWh and 456 kl of water.
Conclusions: The methodology used of how hospital sterilizer use could be improved could be applied to all hospitals and more broadly to other equipment used in hospitals.
Keywords: energy; sterilization; sustainability; water.
© The Author(s) 2016.