A Simple 3-Dimensional Printed Aid for a Corrective Palmar Opening Wedge Osteotomy of the Distal Radius

J Hand Surg Am. 2016 Mar;41(3):464-9. doi: 10.1016/j.jhsa.2015.12.022. Epub 2016 Jan 16.

Abstract

The reconstruction of malunited distal radius fractures is often challenging. Virtual planning techniques and guides for drilling and resection have been used for several years to achieve anatomic reconstruction. These guides have the advantage of leading to better operative results and faster surgery. Here, we describe a technique using a simple implant independent 3-dimensional printed drill guide and template to simplify the surgical reconstruction of a malunited distal radius fracture.

Keywords: 3-dimensional printing; Distal radius mal-union; corrective osteotomy; drill guide; virtual planning.

Publication types

  • Case Reports
  • Review

MeSH terms

  • Bone Wires
  • Fractures, Malunited / surgery*
  • Humans
  • Male
  • Middle Aged
  • Osteotomy / methods*
  • Patient Care Planning
  • Printing, Three-Dimensional*
  • Radius Fractures / surgery*
  • Surgery, Computer-Assisted / methods*