Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration

Bioresour Technol. 2016 Apr:205:174-82. doi: 10.1016/j.biortech.2015.12.088. Epub 2016 Jan 20.

Abstract

The low hydraulic loading rate (HLR) greatly restricts the wide application of subsurface wastewater infiltration system (SWIS) in densely populated areas. To increase the HLR, an innovative SWIS was developed using cyclic operation mode. In each cycle, a wastewater feeding period is followed by a drying period, in which the aeration is conducted by a medium-pressure fan. Results indicated that the removal rate of TOC and NH4(+)-N were more than 85% at HLR of 0.5m(3)/m(2)d, whereas the TN removal rate was lower than 20%, indicating that the aeration was efficient and denitrification process was largely limited in the SWIS. When HLR decreased from 0.5 to 0.2m(3)/m(2)d, the pollutant removal efficiency enhanced slightly except for TN. Overall, the intermittent operation and micro-power aeration, combined with shunting the pollutant loading were really helpful for SWIS to achieve higher HLR, which offers a reference for the design of innovative SWIS.

Keywords: High hydraulic loading rate; Intermittent aeration; Intermittent operation; Oxygen concentration; Subsurface wastewater infiltration system.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aerobiosis
  • Air
  • Ammonia / chemistry
  • Biological Oxygen Demand Analysis
  • Denitrification
  • Nitrogen / chemistry
  • Pilot Projects
  • Sewage
  • Waste Disposal, Fluid / instrumentation*
  • Waste Disposal, Fluid / methods*
  • Wastewater / chemistry
  • Water Pollutants, Chemical / isolation & purification*

Substances

  • Sewage
  • Waste Water
  • Water Pollutants, Chemical
  • Ammonia
  • Nitrogen