Laparoscopic Intraperitonealization of Accidentally Misplaced Peritoneal Dialysis Catheter: A Salvage Procedure

Perit Dial Int. 2016 Jan-Feb;36(1):112-4. doi: 10.3747/pdi.2014.00237.

Abstract

Tenckhoff catheter placement is a well-established procedure to facilitate continuous ambulatory peritoneal dialysis (CAPD) in end-stage renal disease (ESRD) management. Catheter malposition is a possible cause of catheter malfunction. Options to deal with early malfunction are re-exploration, omentectomy, repositioning, or new catheter placement. Technical malpositioning can be dealt with early, with minimal morbidity and cost. Here we report a case of a CAPD catheter accidentally placed preperitoneally which was salvaged using videolaparscopy.

Keywords: Tenckhoff catheter; dialysis; laparoscopy; malposition; renal.

Publication types

  • Case Reports

MeSH terms

  • Catheters, Indwelling*
  • Foreign Bodies / etiology
  • Foreign Bodies / surgery*
  • Humans
  • Laparoscopy*
  • Male
  • Medical Errors*
  • Middle Aged
  • Peritoneal Dialysis*
  • Peritoneum / surgery*