Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?

J Orthop Sci. 2016 May;21(3):327-31. doi: 10.1016/j.jos.2016.01.002. Epub 2016 Feb 11.

Abstract

Background: Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing.

Methods: We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years.

Results: Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months.

Conclusions: Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Age Distribution
  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Hip / adverse effects*
  • Arthroplasty, Replacement, Hip / methods
  • Biomechanical Phenomena
  • Ceramics
  • Cohort Studies
  • Female
  • Follow-Up Studies
  • Hip Dislocation / epidemiology*
  • Hip Dislocation / prevention & control
  • Hip Dislocation / surgery*
  • Hip Prosthesis
  • Humans
  • Incidence
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Postoperative Complications / epidemiology
  • Postoperative Complications / physiopathology
  • Prospective Studies
  • Prosthesis Design*
  • Prosthesis Failure*
  • Reoperation / methods
  • Republic of Korea
  • Sex Distribution
  • Weight-Bearing / physiology*