On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor
- PMID: 27209090
- DOI: 10.1016/j.apradiso.2016.05.017
On-line detection of key radionuclides for fuel-rod failure in a pressurized water reactor
Abstract
For early on-line detection of fuel rod failure, the key radionuclides useful in monitoring must leak easily from failing rods. Yield, half-life, and mass share of fission products that enter the primary coolant also need to be considered in on-line analyses. From all the nuclides that enter the primary coolant during fuel-rod failure, (135)Xe and (88)Kr were ultimately chosen as crucial for on-line monitoring of fuel-rod failure. A monitoring system for fuel-rod failure detection for pressurized water reactor (PWR) based on the LaBr3(Ce) detector was assembled and tested. The samples of coolant from the PWR were measured using the system as well as a HPGe γ-ray spectrometer. A comparison showed the method was feasible. Finally, the γ-ray spectra of primary coolant were measured under normal operations and during fuel-rod failure. The two peaks of (135)Xe (249.8keV) and (88)Kr (2392.1keV) were visible, confirming that the method is capable of monitoring fuel-rod failure on-line.
Keywords: Fission products; Fuel-rod failure; LaBr(3)(Ce) detector; On-line detection.
Copyright © 2016 Elsevier Ltd. All rights reserved.
Similar articles
-
Gamma-gamma coincidence performance of LaBr3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios.Appl Radiat Isot. 2017 Apr;122:116-120. doi: 10.1016/j.apradiso.2017.01.012. Epub 2017 Jan 15. Appl Radiat Isot. 2017. PMID: 28130979
-
On-site gamma-ray spectroscopic measurements of fission gas release in irradiated nuclear fuel.Appl Radiat Isot. 2007 Jan;65(1):36-45. doi: 10.1016/j.apradiso.2006.07.004. Epub 2006 Sep 1. Appl Radiat Isot. 2007. PMID: 16949295
-
Pb(Mg1/3Nb2/3)-PbTiO3-Based Ultrasonic Transducer for Detecting Infiltrated Water in Pressurized Water Reactor Fuel Rods.Sensors (Basel). 2019 Jun 13;19(12):2662. doi: 10.3390/s19122662. Sensors (Basel). 2019. PMID: 31200440 Free PMC article.
-
HPGe/BGO Compton suppression system: Monte Carlo study of radiation monitoring system for failed fuel detection in sodium-cooled fast reactors.Appl Radiat Isot. 2021 Aug;174:109737. doi: 10.1016/j.apradiso.2021.109737. Epub 2021 Apr 29. Appl Radiat Isot. 2021. PMID: 33964524 Review.
-
Determination of ¹³⁵Cs and ¹³⁷Cs in environmental samples: A review.Anal Chim Acta. 2015 Aug 26;890:7-20. doi: 10.1016/j.aca.2015.06.037. Epub 2015 Aug 8. Anal Chim Acta. 2015. PMID: 26347165 Review.
Publication types
LinkOut - more resources
Full Text Sources
Other Literature Sources
