Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction

Circ Cardiovasc Interv. 2016 Jun;9(6):e003426. doi: 10.1161/CIRCINTERVENTIONS.115.003426.

Abstract

Background: The CoreValve US High-Risk Clinical Study compared clinical outcomes and serial echocardiographic findings in patients with severe aortic valve stenosis after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis or surgical aortic valve replacement (SAVR).

Methods and results: Eligible patients were randomly assigned 1:1 to TAVR with a self-expanding bioprosthesis or SAVR (N=747). Echocardiograms were obtained at baseline, discharge, 30 days, 6 months, and 1 year after the procedure and were analyzed at a central core laboratory. Compared with SAVR patients (N=357), TAVR patients (N=390) had a lower mean aortic valve gradient, larger valve area, and less patient-prosthesis mismatch (all P<0.001), but more paravalvular regurgitation at discharge, which decreased at 1 year. SAVR patients experienced significant right ventricular systolic dysfunction at discharge and 1 month with normal right ventricular function at 1 year. One-year all-cause mortality was 14.2% for TAVR and 19.1% for SAVR patients. Preimplantation aortic regurgitation ≥mild was associated with reduced mortality hazard for both the TAVR (hazard ratio 0.48, 95% confidence interval 0.27-0.85; P=0.01) and the SAVR groups (hazard ratio 0.53, 95% confidence interval 0.32-0.87; P=0.01). Aortic regurgitation ≥mild after TAVR was associated with increased risk for all-cause mortality (hazard ratio 1.95, 95% confidence interval 1.08-3.53; P=0.03).

Conclusions: In patients with severe aortic stenosis at increased surgical risk, TAVR was associated with better systolic valve performance, similar left ventricular remodeling, more paravalvular regurgitation, and less right ventricular systolic dysfunction compared with SAVR. Despite an overall mortality reduction for the TAVR group, ≥mild aortic valve regurgitation after TAVR was associated with an increased mortality hazard.

Clinical trial registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01240902.

Keywords: aortic stenosis; echocardiography; mortality; paravalvular regurgitation; surgical aortic valve replacement; transcatheter aortic valve replacement.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / diagnostic imaging
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Stenosis / diagnostic imaging*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Echocardiography, Doppler*
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Predictive Value of Tests
  • Prosthesis Design*
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects
  • Transcatheter Aortic Valve Replacement / instrumentation*
  • Transcatheter Aortic Valve Replacement / mortality
  • Treatment Outcome
  • United States
  • Ventricular Function, Left
  • Ventricular Function, Right
  • Ventricular Remodeling

Associated data

  • ClinicalTrials.gov/NCT01240902