Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation

Am J Cardiol. 2016 Aug 15;118(4):567-71. doi: 10.1016/j.amjcard.2016.05.053. Epub 2016 May 29.

Abstract

The iterations of the SAPIEN prosthesis might impact the incidence and grade of paravalvular regurgitation (PVR). The aim of this study was to assess the impact of iterations of balloon-expandable valves (SAPIEN, SAPIEN XT, and SAPIEN 3) and degree of aortic valve calcification (AVC) on the severity of PVR after transcatheter aortic valve implantation (TAVI). Comprehensive echocardiographic examinations and multidetector computed tomography (MDCT) were performed in 272 patients (127 men, 81 ± 7 years old, logistic EuroScore of 21 ± 13%) who underwent TAVI with 23- and 26-mm balloon-expandable valves. The degree of AVC was assessed with MDCT. PVR grade was assessed with echocardiography. The cover index was calculated as (prosthesis area - MDCT annulus area)/prosthesis area. SAPIEN, SAPIEN XT, and SAPIEN 3 prostheses were implanted in 103 patients (38%), 105 patients (38.5%), and 64 patients (23.5%), respectively. Significant PVR (≥moderate) occurred in 14%, 10%, and 0% of patients receiving the SAPIEN, SAPIEN XT, and SAPIEN 3, respectively (p = 0.010). Across the groups, the aortic annulus size, degree of calcification, and cover index were comparable. Larger burden of AVC was independently associated with significant PVR (odds ratio 3.48, p = 0.006) after adjusting for age, body surface area, gender, aortic annulus area, cover index, and prosthesis iteration. SAPIEN 3 was associated with lower frequency of significant PVR (odds ratio 0.31, p = 0.002). In conclusion, the incidence of significant PVR significantly decreased over time with improvement in valve design. SAPIEN 3 was associated with less significant PVR after TAVI independently of the AVC burden.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / pathology*
  • Aortic Valve / surgery
  • Aortic Valve Insufficiency / epidemiology*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / surgery*
  • Bioprosthesis*
  • Calcinosis / diagnostic imaging
  • Calcinosis / surgery*
  • Echocardiography
  • Female
  • Heart Valve Prosthesis*
  • Humans
  • Logistic Models
  • Male
  • Multidetector Computed Tomography
  • Multivariate Analysis
  • Postoperative Complications / epidemiology*
  • Prosthesis Design
  • Retrospective Studies
  • Severity of Illness Index
  • Transcatheter Aortic Valve Replacement / instrumentation
  • Transcatheter Aortic Valve Replacement / methods*

Supplementary concepts

  • Aortic Valve, Calcification of