Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial

BMC Ophthalmol. 2016 Jul 8:16:100. doi: 10.1186/s12886-016-0283-4.

Abstract

Background: To compare the in-the-bag stability and visual function of single-piece intraocular lenses (IOLs) and three-piece IOLs.

Methods: A total of 65 patients with age-related cataracts (80 eyes) were enrolled and randomly assigned to receive in-the-bag implantation of either a single-piece IOL (40 eyes) or a three-piece IOL (40 eyes). Follow-up visits were conducted at 1 week, 1 month and 3 months postoperatively. Visual acuity, refraction and total aberration were examined. IOL position stability (including axial movement, decentration and tilt) was measured using a Scheimpflug imaging system.

Results: At the 3-month follow-up visit, single-piece IOLs did not exhibit significant axial movement (0.07 ± 0.30 mm, p = 0.13) compared with their axial position at 1 week postoperatively, whereas three-piece IOLs displayed forward axial movement of -0.22 ± 0.23 mm (p < 0.0001). The mean manifest spherical equivalence (SE) of eyes with single-piece IOL was 0.15 ± 0.18D, whereas in eyes with three-piece IOLs, the mean manifest SE was -0.34 ± 0.15D (p < 0.001). There was no statistically significant difference in IOL decentration, tilt, uncorrected visual acuity, best-corrected visual acuity or total spherical aberration between the two groups.

Conclusions: Three months after implantation, single-piece IOLs exhibit better axial stability and more stable refractive outcome than three-piece IOLs, but both IOLs perform equally well in terms of decentration, tilt, visual acuity and total aberration.

Trial registration: ClinicalTrial.gov, NCT02609997 , 11/18/2015, retrospectively registered.

Keywords: Cataract surgery; In-the-bag stabilities; Single-piece intraocular lenses; Three-piece intraocular lenses.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Aged, 80 and over
  • Anterior Eye Segment / pathology
  • Female
  • Follow-Up Studies
  • Humans
  • Lens Implantation, Intraocular*
  • Lenses, Intraocular*
  • Male
  • Middle Aged
  • Phacoemulsification*
  • Prosthesis Design
  • Refraction, Ocular / physiology
  • Retrospective Studies
  • Visual Acuity / physiology

Associated data

  • ClinicalTrials.gov/NCT02609997