Purpose: To assess the feasibility and safety of the 7 French (Fr) Glidesheath Slender for complex transradial (TR) percutaneous coronary interventions (PCI).
Background: The TR approach is increasingly used worldwide for coronary and peripheral vascular interventions. However, the small size of the radial artery remains an important limitation for the use of large-bore guiding catheters (>6 Fr), restricting thereby the treatment of highly complex lesions through the TR approach. The 7 Fr Glidesheath slender (Terumo, Tokyo, Japan) is a new dedicated radial sheath with a thinner wall and hydrophilic coating. It combines an inner diameter compatible with any 7 Fr guiding catheter and an outer diameter smaller than current 7 Fr sheaths.
Methods: Prospective multicenter registry of complex TR PCI cases using the 7 Fr Glidesheath Slender to determine the procedural success, rates of vascular complications, radial spasm, and radial artery occlusion (RAO).
Results: A total of 60 patients were included. Procedural success was 97% with only one access-site crossover. The use of a 7 Fr guiding catheter was indicated for the treatment of highly complex coronary lesions including distal left main (LM) disease (n = 20), complex non-LM bifurcation lesions (n = 16), chronic total occlusion (n = 15), and severely calcified vessels requiring rotational atherectomy (n = 10). There were three vascular access-site complications (4.7%) including two moderate (type II) local hematoma and one uncomplicated guiding catheter-induced brachial artery dissection. None of the patients experienced major bleeding. The occurrence of radial spasm was reported in seven patients (11%). Doppler ultrasound imaging of the radial artery at 1 month was available in 62 of 64 radial access with three cases of RAO (4.8%).
Conclusions: Use of the 7 Fr Glidesheath slender for complex coronary interventions is feasible and associated with a high rate of procedural success and a low rate of vascular complications. These favorable results need be confirmed in larger multicenter studies. © 2016 Wiley Periodicals, Inc.
Keywords: complex PCI; radial occlusion; radial sheath; slender; transradial access; transradial approach.
© 2016 Wiley Periodicals, Inc.