Background: Lichtenstein hernioplasty has relatively low recurrence rate, but chronic inguinal pain may cause harm to the patient. The aim of our study was to compare long-term results of cyanoacrylate glue versus absorbable sutures for mesh fixation in Lichtenstein hernioplasty.
Methods: Lichtenstein hernioplasty (n = 302) was performed under local anesthesia in three hospitals. The patients were randomized to receive either 1 ml of butyl-2-cyanoacrylate tissue glue (Glubran®; 151 hernias) or absorbable polyglycolic acid sutures (Dexon®; 151 hernias) for mesh fixation (Optilene® mesh). Short-term results were published previously. Chronic groin pain, foreign body sensation, use of analgesics, recurrence and re-operations were analyzed 7 years after surgery.
Results: We reached 236 patients (78%) to present study. In the glue group (n = 115), there were five (4.3%) and in the suture group (n = 121) three (2.5%) recurrent hernias (p = 0.491). The prevalence of chronic pain (NRS ≥ 3) in the patients without re-operations was similar in two groups: 15/118 (13%) and 13/111 (12%), respectively (p = 0.843). There were no significant differences in the foreign body sensation (8/14, p = 0.267) or in the need of analgesics (2/2, p = 1.00) between the two study groups.
Conclusion: Both cyanoacrylate glue and mesh fixation with absorbable sutures were equal in terms of chronic pain and rate of recurrences in Lichtenstein hernioplasty after 7-year follow-up.
Trial registration number: NCT00659542.