Background: The diagnosis of obstructive sleep apnea/hypopnea syndrome (OSAHS) is essential but polysomnography (PSG) is expensive and time consuming. Oximetry has been used as a less expensive indicator of OSAHS. The aim of the study was to evaluate the clinical utility of the combination of oximetry with four different questionnaires: Stop, Stop Bang (S-B), Berlin questionnaire (BQ), Epworth Sleepiness Scale (ESS) in order to identify patients at risk for OSAHS compared with in-laboratory PSG.
Methods: Patients visiting a sleep clinic were prospectively studied. They completed Stop, S-B, BQ and ESS. Home oximetry and in laboratory PSG were performed within 3-20 days.
Results: A total of 204 patients were included in the study (77.5% males, mean age 51.8±13.8 years, BMI 32.8±6.2 kg/m2, SaO2% awake 95.7±2). S-B had the highest sensitivity (Se) (97.5%) and negative predictive value (NPV) (62.5%) but the lowest specificity (Sp) (9%), whereas ESS had the best Sp (75%) and positive predictive values (PPV) (81.4%). The predictive values of questionnaires improved as the severity of OSAHS worsened. The predictive values of oximetry were high for severe but low for mild and moderate OSAHS. For that oximetry was combined with different sleep questionnaires in different OSAHS severity groups, but with no improvement in the predictive values.
Conclusions: Oximetry may be used as a tool for identifying severe OSAHS. For mild and moderate disease the combination of questionnaires did not improve the diagnostic accuracy and especially for symptomatic patients with negative results, the need of PSG is essential.
Keywords: Berlin questionnaire (BQ); Epworth Sleepiness Scale (ESS); Oximetry; Stop; Stop-Bang (S-B); sleep apnea.