Absence of in vivo mutagenicity of multi-walled carbon nanotubes in single intratracheal instillation study using F344 gpt delta rats

Genes Environ. 2017 Jan 6:39:4. doi: 10.1186/s41021-016-0065-5. eCollection 2017.

Abstract

Introduction: It is known that fibrous particles of micrometer length, such as carbon nanotubes, which have same dimensions as asbestos, are carcinogenic. Carcinogenicity of nanomaterials is strongly related to inflammatory reactions; however, the genotoxicity mechanism(s) is unclear. Indeed, inconsistent results on genotoxicity of multi-walled carbon nanotubes (MWCNTs) have been shown in several reports. Therefore, we analyzed the in vivo genotoxicity induced by an intratracheal instillation of straight MWCNTs in rats using a different test system-the Pig-a gene mutation assay-that can reflect the genotoxicity occurring in the bone marrow. Since lungs were directly exposed to MWCNTs upon intratracheal instillation, we also performed the gpt assay using the lungs.

Findings: We detected no significant differences in Pig-a mutant frequencies (MFs) between the MWCNT-treated and control rats. Additionally, we detected no significant differences in gpt MFs in the lung between the MWCNT-treated and control rats.

Conclusions: Our findings indicated that a single intratracheal instillation of MWCNTs was non-mutagenic to both the bone marrow and lung of rats.

Keywords: Carbon nanoparticle; Multi-walled carbon nanotubes; Pig-a gene mutation assay; in vivo genotoxicity.

Publication types

  • Case Reports