Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing
- PMID: 28185351
- DOI: 10.1111/jce.13179
Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing
Abstract
Introduction: Arrhythmia recurrences remain common after ablation of persistent atrial fibrillation (PersAF). Contact force (CF)-sensing catheters have been introduced for objective assessment of contact during radiofrequency application and have been suggested to improve outcomes in ablation of paroxysmal AF, but little is known about their role in PersAF ablation. We aimed to compare the procedural profiles and outcomes of (PersAF) ablation with or without using CF-sensing catheters.
Methods: All consecutive patients undergoing first time ablation for PersAF between April 2014 and January 2015 at the Cleveland Clinic were included. Substrate modification was performed in addition to isolation of the pulmonary veins. Success rates were determined off antiarrhythmics over 1 year of follow-up.
Results: The study included 174 patients (77 CF and 97 non-CF). Ablation with CF-sensing catheters resulted in shorter procedures (median 204 vs. 216 minutes, P = 0.04) and shorter fluoroscopy time (36 vs. 48 minutes, P = 0.0005), without statistical difference in radiation dose (225 vs. 270 milligrays, P = 0.1). Arrhythmia recurrences were less likely to be observed in the CF-sensing group (27.6% vs. 46.4%, P = 0.01, log-rank P = 0.004). In multivariable Cox analyses, the use of CF-sensing catheters was associated with a lower risk of arrhythmia recurrence (hazard ratio 0.49, 95% confidence interval 0.27-0.85, P = 0.01).
Conclusions: Compared to non-CF sensing, the use of CF-sensing catheters for PersAF ablation is associated with shorter procedures, shorter fluoroscopy time, and reduction in arrhythmia recurrences.
Keywords: ablation; contact force; persistent atrial fibrillation.
© 2017 Wiley Periodicals, Inc.
Similar articles
-
Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.Europace. 2015 May;17(5):718-24. doi: 10.1093/europace/euv060. Epub 2015 Apr 2. Europace. 2015. PMID: 25840289
-
Influence of energy source on early atrial fibrillation recurrences: a comparison of cryoballoon vs. radiofrequency current energy ablation with the endpoint of unexcitability in pulmonary vein isolation.Europace. 2018 Jan 1;20(1):43-49. doi: 10.1093/europace/euw307. Europace. 2018. PMID: 27742775 Clinical Trial.
-
Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry.Europace. 2018 Nov 1;20(FI_3):f410-f418. doi: 10.1093/europace/eux290. Europace. 2018. PMID: 29315382
-
Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta-Analysis.J Am Heart Assoc. 2015 Sep 21;4(9):e002476. doi: 10.1161/JAHA.115.002476. J Am Heart Assoc. 2015. PMID: 26391136 Free PMC article. Review.
-
The impact of adjunctive complex fractionated atrial electrogram ablation and linear lesions on outcomes in persistent atrial fibrillation: a meta-analysis.Europace. 2016 Mar;18(3):359-67. doi: 10.1093/europace/euv351. Epub 2015 Nov 10. Europace. 2016. PMID: 26559915 Review.
Cited by
-
Transcatheter options for atrial fibrillation treatment: an overview of the ablative techniques currently available and future perspectives.Ann Cardiothorac Surg. 2024 Jan 30;13(1):31-43. doi: 10.21037/acs-2023-afm-0060. Epub 2023 Aug 8. Ann Cardiothorac Surg. 2024. PMID: 38380136 Free PMC article. Review.
-
High-Power Short-Duration Lesion Index-Guided Posterior Wall Isolation beyond Pulmonary Vein Isolation for Persistent Atrial Fibrillation.J Clin Med. 2023 Aug 11;12(16):5228. doi: 10.3390/jcm12165228. J Clin Med. 2023. PMID: 37629269 Free PMC article.
-
Catheter ablation for the management of atrial fibrillation: current technical perspectives.Open Heart. 2020 May;7(1):e001207. doi: 10.1136/openhrt-2019-001207. Open Heart. 2020. PMID: 32393656 Free PMC article. Review.
-
Safety and efficacy of the ThermoCool SmartTouch SurroundFlow catheter for atrial fibrillation ablation: A meta-analysis.Clin Cardiol. 2020 Mar;43(3):267-274. doi: 10.1002/clc.23297. Epub 2019 Nov 19. Clin Cardiol. 2020. PMID: 31743474 Free PMC article.
-
The industrialization of ablation: a highly standardized and reproducible workflow for radiofrequency ablation of atrial fibrillation.J Interv Card Electrophysiol. 2020 Oct;59(1):21-27. doi: 10.1007/s10840-019-00622-y. Epub 2019 Oct 17. J Interv Card Electrophysiol. 2020. PMID: 31625008 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical