Background and objectives: Occupational exposure to waste anesthetic gases in operating room (OR) without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhaled anesthetics isoflurane and sevoflurane in OR with and without central scavenging system.
Method: Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120minutes after the start of surgery) in both OR types.
Results: All isoflurane and sevoflurane concentrations in unscavenged OR were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged OR, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times.
Conclusions: The exposure to both anesthetics exceeded the international limit in unscavenged OR. In scavenged OR, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the OR scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.
Keywords: Anestésicos inalatórios; Exposição ocupacional; Indoor air pollution; Inhaled anesthetics; Occupational exposure; Operating rooms; Poluição do ar em ambientes fechados; Salas cirúrgicas.