N-Terminal Pro-B-Type Natriuretic Peptide and Phonocardiography in Differentiating Innocent Cardiac Murmurs from Congenital Cardiac Anomalies in Asymptomatic Puppies

J Vet Intern Med. 2017 May;31(3):661-667. doi: 10.1111/jvim.14667. Epub 2017 Mar 18.

Abstract

Background: Differentiating innocent cardiac murmurs from murmurs caused by congenital cardiac anomalies can be challenging with auscultation alone in asymptomatic puppies.

Hypothesis: Plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) concentrations and phonocardiograms recorded by an electronic stethoscope can differentiate innocent from pathologic cardiac murmurs.

Animals: A total of 186 client-owned asymptomatic dogs: 135 Cairn Terriers (age: 45-124 days), 20 adult Cairn Terriers (age: 7.5 months to 13.5 years), and 31 puppies of various breeds (age: 29-396 days).

Methods: Study design is a cross-sectional survey. Each dog was auscultated, and when a cardiac murmur was heard, a phonocardiogram was recorded and an echocardiogram was performed. Plasma NT-proBNP concentrations were measured by a single laboratory by an ELISA.

Results: No significant (P = .41) difference in plasma NT-proBNP levels was found between puppies without a murmur and puppies with an innocent murmur (median 300 versus 326 pmol/L), and between clinically healthy adult Cairn Terriers and Cairn Terrier puppies. Plasma NT-proBNP levels in puppies with a congenital heart disease were significantly (P < .001) higher than those in puppies with innocent murmurs (median 1,102 versus 326 pmol/L). However, some puppies with severe pulmonic stenosis did not have increased plasma NT-proBNP levels. On phonocardiograms, innocent murmurs had a significantly (P < .001) shorter "murmur-to-systole duration ratio" than the abnormal ones (median 66 versus 100%). The "murmur-to-S1 (first cardiac sound) amplitude ratio" was significantly (P < .001) lower of the innocent murmurs compared with that of the abnormal ones (median 16 versus 58 %).

Conclusions and clinical importance: Plasma NT-proBNP concentrations within the reference range do not rule out a congenital cardiac anomaly. Murmurs longer than 80% of the systole are most likely abnormal, whereas murmurs shorter than that could be either innocent or pathologic.

Keywords: Auscultation; Biomarker; Breed; Cairn Terrier; Dogs; Echocardiography; Functional murmurs; Littmann Electronic Stethoscope; Phonendoscope.

MeSH terms

  • Animals
  • Animals, Newborn
  • Biomarkers / blood*
  • Dog Diseases / blood*
  • Dog Diseases / diagnostic imaging
  • Dogs
  • Echocardiography / veterinary
  • Female
  • Heart Auscultation / veterinary
  • Heart Defects, Congenital / blood
  • Heart Defects, Congenital / veterinary*
  • Heart Murmurs / blood
  • Heart Murmurs / veterinary*
  • Male
  • Natriuretic Peptide, Brain / blood*
  • Peptide Fragments / blood*
  • Predictive Value of Tests

Substances

  • Biomarkers
  • Peptide Fragments
  • pro-brain natriuretic peptide (1-76)
  • Natriuretic Peptide, Brain