The diagnostic performance of 18F-FDG PET/CT, CT and MRI in the treatment evaluation of ablation therapy for colorectal liver metastases: A systematic review and meta-analysis

Surg Oncol. 2017 Mar;26(1):37-45. doi: 10.1016/j.suronc.2016.12.006. Epub 2016 Dec 29.

Abstract

Purpose: Uncertainty exists regarding the optimal imaging modality for timely detection of disease progression (DP) after ablation therapy for colorectal liver metastases. We evaluated the diagnostic accuracy of 18F-FDG PET(/CT), CT and MRI for detection of DP following ablation therapy.

Methods: A systematic search was performed on May 18, 2016. The analysis included studies that reported on the diagnostic accuracy of 18F-FDG PET(/CT), CT and/or MRI for post-ablative evaluation of patients with liver metastases. Primary outcome was the diagnostic accuracy of the imaging modalities for detection of DP. Methodological quality was assessed using the QUADAS-2 tool. Pooled sensitivities and specificities were estimated using bivariate random-effects models.

Results: Ten studies were included in the meta-analysis, including seven comparative studies. Nine reported data on diagnostic accuracy of 18F-FDG PET(/CT), seven on CT imaging. Only two studies reported the diagnostic accuracy of MRI, hence not included in the meta-analysis. Quality assessment raised concerns about the risk of bias regarding the use of the reference standard, blinding of the index tests and the follow-up time. Pooled sensitivity was respectively 84.6% (75.0-90.6) and 53.4% (29.0-76.4) for 18F-FDG PET(/CT) and CT (P = 0.005). Pooled specificity was respectively 92.4% (86.5-95.9) and 95.7% (87.5-98.6) (P = 0.392).

Conclusion: 18F-FDG PET/(CT) yields a higher sensitivity for detecting DP after ablation therapy compared with CT and has a comparably high specificity. These findings indicate that the use of 18F-FDG PET(/CT) in this setting particularly allows for minimization of the false-negative rate compared with CT without compromising the low false-positive rate.

Keywords: Accuracy; Hepatic metastases; Nuclear imaging; RFA.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Catheter Ablation / methods*
  • Colorectal Neoplasms / diagnostic imaging
  • Colorectal Neoplasms / pathology*
  • Colorectal Neoplasms / therapy
  • Fluorodeoxyglucose F18*
  • Humans
  • Liver Neoplasms / diagnostic imaging
  • Liver Neoplasms / secondary*
  • Liver Neoplasms / therapy
  • Magnetic Resonance Imaging / methods*
  • Multimodal Imaging / methods*
  • Positron Emission Tomography Computed Tomography / methods*
  • Radiopharmaceuticals*
  • Tomography, X-Ray Computed / methods*

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18