Preliminary evaluation of discomfort glare from organic light-emitting diode and edge-lit light-emitting diode lighting panels
- PMID: 28498933
- DOI: 10.1117/1.JBO.22.5.055004
Preliminary evaluation of discomfort glare from organic light-emitting diode and edge-lit light-emitting diode lighting panels
Abstract
The organic light-emitting diode (OLED) is an area light source, and its primary competing technology is the edge-lit light-emitting diode (LED) panel. Both technologies are similar in shape and appearance, but there is little understanding of how people perceive discomfort glare (DG) from area sources. The objective of this study was to evaluate the DG of these two technologies under similar operating conditions. Additionally, two existing DG models were compared to evaluate the correlation between predicted values and observed values. In an earlier study, we found no statistically significant difference in human response in terms of DG between OLED and edge-lit LED panels when the two sources produced the same luminous stimulus. The range of testing stimulus was expanded to test different panel luminances at three background illuminations. The results showed no difference in perceived glare between the panels, and, as the background illumination increased, the perceived glare decreased. In other words, both appeared equally glary beyond a certain luminance and background illumination. We then compared two existing glare models with the observed values and found that one model showed a good estimation of how humans perceive DG. That model was further modified to increase its power.
Similar articles
-
Flicker-glare and visual-comfort assessments of light emitting diode billboards.Appl Opt. 2014 Aug 1;53(22):E61-8. doi: 10.1364/AO.53.000E61. Appl Opt. 2014. PMID: 25090356 Clinical Trial.
-
LED Area Lighting to Reduce Glare for Roof Bolter Operators.Min Metall Explor. 2020;37(3):851-860. doi: 10.1007/s42461-020-00193-x. Min Metall Explor. 2020. PMID: 32685916 Free PMC article.
-
Model predicting discomfort glare caused by LED road lights.Opt Express. 2014 Jul 28;22(15):18056-71. doi: 10.1364/OE.22.018056. Opt Express. 2014. PMID: 25089425
-
[The dangers of blue light: True story!].J Fr Ophtalmol. 2016 May;39(5):483-8. doi: 10.1016/j.jfo.2016.02.003. Epub 2016 Mar 31. J Fr Ophtalmol. 2016. PMID: 27039979 Review. French.
-
Electrical behaviour of MEH-PPV based diode and transistor.Prog Biophys Mol Biol. 2013 Nov;113(2):289-94. doi: 10.1016/j.pbiomolbio.2013.09.002. Epub 2013 Sep 27. Prog Biophys Mol Biol. 2013. PMID: 24080185 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
