Effect of a Low-Rank Denoising Algorithm on Quantitative Magnetic Resonance Imaging-Based Measures of Liver Fat and Iron

J Comput Assist Tomogr. 2017 May/Jun;41(3):412-416. doi: 10.1097/RCT.0000000000000535.

Abstract

Purpose: This study aimed to assess the effect of a low-rank denoising algorithm on quantitative magnetic resonance imaging-based measures of liver fat and iron.

Materials and methods: This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant, retrospective analysis of 42 consecutive subjects who were imaged at 3T using a multiecho gradient echo sequence that was reconstructed using the multistep adaptive fitting algorithm to obtain quantitative proton density fat fraction (PDFF) and R2* maps (original maps). A patch-wise low-rank denoising algorithm was then applied, and PDFF and R2* maps were created (denoised maps). Three readers independently rated the PDFF maps in terms of vessel and liver edge sharpness and image noise using a 5-point scale. Two other readers independently measured mean and standard deviation of PDFF and R2* values for the original and denoised maps; values were compared using intraclass correlation coefficients (ICCs) and mean difference analyses.

Results: Qualitatively, the denoised maps were preferred by all 3 readers based on image noise (P < 0.001) and by 2 of 3 readers based on vessel edge sharpness (P < 0.001-0.99). No reader had a significant preference regarding liver edge sharpness (P = 0.16-0.48). Quantitatively, agreement was near perfect between the original and denoised maps for PDFF (ICC = 0.995) and R2* (ICC = 0.995) values. Mean quantitative values obtained from the original and denoised maps were similar for liver PDFF (7.6 ± 7.7% vs 7.7 ± 7.8%; P = 0.63) and R2* (52.9 ± 40.3s vs 52.8 ± 41.1 s, P = 0.74).

Conclusions: Applying the low-rank denoising algorithm to liver fat and iron quantification reduces image noise in PDFF and R2* maps without adversely affecting mean quantitative values or subjective image quality.

Publication types

  • Evaluation Study

MeSH terms

  • Adipocytes*
  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms*
  • Evaluation Studies as Topic
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Image Processing, Computer-Assisted / methods
  • Iron / metabolism*
  • Liver / diagnostic imaging*
  • Liver / metabolism
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Retrospective Studies
  • Young Adult

Substances

  • Iron