Purpose: To evaluate the manifestation of meibomian gland dysfunction in patients with Sjögren's syndrome (SS), non-Sjögren's syndrome dry eye (non-SS) patients, and non-dry eye controls.
Methods: We recruited 31 participants with SS dry eye, 30 participants with non-SS dry eye, and 35 healthy controls without dry eye symptoms. Noninvasive tear breakup time (NITBUT) and meibomian gland dropout score (meiboscore) were measured using the Oculus Keratograph 5 M. Meibomian gland expressibility and secretion quality were evaluated via slit lamp biomicroscopy. The correlation between measurements was analyzed.
Results: NITBUT was lower, and the meiboscore, meibomian gland expressibility, and secretion quality scores were significantly higher in the SS and non-SS groups than in the control group (p < 0.001). NITBUT was lower, and the meiboscore and meibomian gland expressibility were higher in the SS group than in the non-SS group. NITBUT correlated negatively with the meiboscore in both SS and non-SS groups and with meibomian gland expressibility in the SS group. A positive correlation was obtained between meiboscore and meibomian gland expressibility in both the SS and the non-SS groups.
Conclusion: Patients in both SS and non-SS groups exhibited greater impairment in meibomian gland function than the non-dry eye controls. SS patients had more severe meibomian gland dysfunction with poorer mean meiboscore and meibomian gland expressibility than non-SS patients.
Keywords: Dry eye; Meibography; Meibomian gland dysfunction; Sjögren’s syndrome.