Generating ActiGraph Counts from Raw Acceleration Recorded by an Alternative Monitor
- PMID: 28604558
- DOI: 10.1249/MSS.0000000000001344
Generating ActiGraph Counts from Raw Acceleration Recorded by an Alternative Monitor
Abstract
Purpose: This study aimed to implement an aggregation method in Matlab for generating ActiGraph counts from raw acceleration recorded with an alternative accelerometer device and to investigate the validity of the method.
Methods: The aggregation method, including the frequency band-pass filter, was implemented and optimized based on standardized sinusoidal acceleration signals generated in Matlab and processed in the ActiLife software. Evaluating the validity of the aggregation method was approached using a mechanical setup and with a 24-h free-living recording using a convenient sample of nine subjects. Counts generated with the aggregation method applied to Axivity AX3 raw acceleration data were compared with counts generated with ActiLife from ActiGraph GT3X+ data.
Results: An optimal band-pass filter was fitted resulting in a root-mean-square error of 25.7 counts per 10 s and mean absolute error of 15.0 counts per second across the full frequency range. The mechanical evaluation of the proposed aggregation method resulted in an absolute mean ± SD difference of -0.11 ± 0.97 counts per 10 s across all rotational frequencies compared with the original ActiGraph method. Applying the aggregation method to the 24-h free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 s, a relative difference in the averaged physical activity (counts per minute) ranging from -0.5% to 4.7% with a group mean ± SD of 2.2% ± 1.7%, and a Cohen's kappa of 0.945, indicating almost a perfect agreement in the intensity classification.
Conclusion: The proposed band-pass filter and aggregation method is highly valid for generating ActiGraph counts from raw acceleration data recorded with alternative devices. It would facilitate comparability between studies using different devices collecting raw acceleration data.
Similar articles
-
Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts.J Appl Physiol (1985). 2016 Feb 1;120(3):362-9. doi: 10.1152/japplphysiol.00628.2015. Epub 2015 Dec 3. J Appl Physiol (1985). 2016. PMID: 26635347
-
Biomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts.Physiol Meas. 2012 Feb;33(2):219-30. doi: 10.1088/0967-3334/33/2/219. Epub 2012 Jan 20. Physiol Meas. 2012. PMID: 22260902 Free PMC article. Clinical Trial.
-
The ActiGraph counts processing and the assessment of vigorous activity.Clin Physiol Funct Imaging. 2019 Jul;39(4):276-283. doi: 10.1111/cpf.12571. Epub 2019 May 2. Clin Physiol Funct Imaging. 2019. PMID: 30980611
-
Mechanical and free living comparisons of four generations of the Actigraph activity monitor.Int J Behav Nutr Phys Act. 2012 Sep 12;9:113. doi: 10.1186/1479-5868-9-113. Int J Behav Nutr Phys Act. 2012. PMID: 22971175 Free PMC article.
-
ActiGraph and Actical physical activity monitors: a peek under the hood.Med Sci Sports Exerc. 2012 Jan;44(1 Suppl 1):S86-9. doi: 10.1249/MSS.0b013e3182399f5e. Med Sci Sports Exerc. 2012. PMID: 22157779 Free PMC article. Review.
Cited by 13 articles
-
Everyday bodily movement is associated with creativity independently from active positive affect: a Bayesian mediation analysis approach.Sci Rep. 2020 Jul 20;10(1):11985. doi: 10.1038/s41598-020-68632-9. Sci Rep. 2020. PMID: 32686709 Free PMC article.
-
TOPS - a randomized controlled trial of exercise and education to prevent recurrence of low back pain: statistical analysis plan.Braz J Phys Ther. 2020 Jul-Aug;24(4):373-380. doi: 10.1016/j.bjpt.2020.05.001. Epub 2020 May 18. Braz J Phys Ther. 2020. PMID: 32451161 Free PMC article. Clinical Trial.
-
Short-term efficacy of reducing screen media use on physical activity, sleep, and physiological stress in families with children aged 4-14: study protocol for the SCREENS randomized controlled trial.BMC Public Health. 2020 Mar 23;20(1):380. doi: 10.1186/s12889-020-8458-6. BMC Public Health. 2020. PMID: 32293374 Free PMC article.
-
Stronger Association between High Intensity Physical Activity and Cardiometabolic Health with Improved Assessment of the Full Intensity Range Using Accelerometry.Sensors (Basel). 2020 Feb 18;20(4):1118. doi: 10.3390/s20041118. Sensors (Basel). 2020. PMID: 32085652 Free PMC article.
-
Upper limb activity of twenty myoelectric prosthesis users and twenty healthy anatomically intact adults.Sci Data. 2019 Oct 10;6(1):199. doi: 10.1038/s41597-019-0211-6. Sci Data. 2019. PMID: 31601805 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
