Accurate analytical method for human plasma glucagon levels using liquid chromatography-high resolution mass spectrometry: comparison with commercially available immunoassays
- PMID: 28801845
- DOI: 10.1007/s00216-017-0534-0
Accurate analytical method for human plasma glucagon levels using liquid chromatography-high resolution mass spectrometry: comparison with commercially available immunoassays
Abstract
Accurate quantification of plasma glucagon levels in humans is necessary for understanding the physiological and pathological importance of glucagon. Although several immunoassays for glucagon are available, they provide inconsistent glucagon values owing to cross-reactivity of the antibodies with peptides other than glucagon. To overcome this limitation, we developed a novel method to measure glucagon levels by a liquid chromatography (LC)-high-resolution mass spectrometry (HRMS) assay via parallel reaction monitoring (PRM) without immunoaffinity enrichment. Using stable isotope-labeled glucagon as an internal standard and 200 μL of plasma, the lower limit of quantification was 0.5 pM. This method was applied to measure plasma glucagon levels during the oral glucose tolerance test (OGTT) and meal tolerance test (MTT) in healthy volunteers, and its results were compared with those of sandwich enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA). During the OGTT, this method showed significant suppression of plasma glucagon levels, and similar patterns were observed with sandwich ELISA and RIA. In contrast, during the MTT, plasma glucagon levels were slightly elevated according to the LC-MS/MS and sandwich ELISA results and were reduced according to RIA results. Our newly developed LC-MS/MS method overcomes a lack of specificity among currently available immunoassays for glucagon and may contribute to a better understanding of the importance of glucagon. Graphical abstract Flowchart for the extraction and quantification of glucagon in human plasma, and plasma glucagon responses in healthy volunteers quantified by the present LC-MS/MS, sandwich ELISA, and RIA during OGTT and MTT.
Keywords: Glucagon; LC-MS/MS; Parallel reaction monitoring; RIA; Sandwich ELISA.
Similar articles
-
Infliximab quantitation in human plasma by liquid chromatography-tandem mass spectrometry: towards a standardization of the methods?Anal Bioanal Chem. 2017 Feb;409(5):1195-1205. doi: 10.1007/s00216-016-0045-4. Epub 2016 Nov 8. Anal Bioanal Chem. 2017. PMID: 27826630
-
Comparison of Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry Methods in the Measurement of Serum Androstenedione Levels.Clin Lab. 2018 Jan 1;64(1):69-75. doi: 10.7754/Clin.Lab.2017.170612. Clin Lab. 2018. PMID: 29479885
-
Quantification of 15-F2t-isoprostane in human plasma and urine: results from enzyme-linked immunoassay and liquid chromatography/tandem mass spectrometry cannot be compared.Rapid Commun Mass Spectrom. 2011 Feb 28;25(4):463-8. doi: 10.1002/rcm.4871. Rapid Commun Mass Spectrom. 2011. PMID: 21259353
-
Androgen glucuronides analysis by liquid chromatography tandem-mass spectrometry: could it raise new perspectives in the diagnostic field of hormone-dependent malignancies?J Chromatogr B Analyt Technol Biomed Life Sci. 2013 Dec 1;940:24-34. doi: 10.1016/j.jchromb.2013.09.022. Epub 2013 Sep 27. J Chromatogr B Analyt Technol Biomed Life Sci. 2013. PMID: 24140653 Review.
-
Sensitive glucagon quantification by immunochemical and LC-MS/MS methods.Bioanalysis. 2013 Dec;5(23):2957-72. doi: 10.4155/bio.13.264. Bioanalysis. 2013. PMID: 24295121 Review.
Cited by
-
Glucagon: Physiological and Pharmacological Functions and Pathophysiological Significance in Type 2 Diabetes.Endocrinol Metab (Seoul). 2024 Feb;39(1):33-39. doi: 10.3803/EnM.2024.1911. Epub 2024 Feb 22. Endocrinol Metab (Seoul). 2024. PMID: 38417825 Free PMC article.
-
High Doses of Exogenous Glucagon Stimulate Insulin Secretion and Reduce Insulin Clearance in Healthy Humans.Diabetes. 2024 Mar 1;73(3):412-425. doi: 10.2337/db23-0201. Diabetes. 2024. PMID: 38015721
-
Simultaneous monitoring of multiple hormones from human islets of Langerhans using solid-phase extraction-mass spectrometry.Anal Bioanal Chem. 2023 Sep;415(23):5671-5680. doi: 10.1007/s00216-023-04837-x. Epub 2023 Jul 14. Anal Bioanal Chem. 2023. PMID: 37442843
-
Newly discovered knowledge pertaining to glucagon and its clinical applications.J Diabetes Investig. 2023 Jul;14(7):829-837. doi: 10.1111/jdi.14009. Epub 2023 Apr 13. J Diabetes Investig. 2023. PMID: 37052948 Free PMC article. Review.
-
Quantitative analysis of therapeutic proteins in biological fluids: recent advancement in analytical techniques.Drug Deliv. 2023 Dec;30(1):2183816. doi: 10.1080/10717544.2023.2183816. Drug Deliv. 2023. PMID: 36880122 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
