Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers

Ann Work Expo Health. 2017 Aug 1;61(7):784-796. doi: 10.1093/annweh/wxx057.

Abstract

Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers.

Keywords: exposure measurement; sampler performance; sampling efficiency; thoracic aerosol.

MeSH terms

  • Aerosols / analysis*
  • Air Pollutants, Occupational / analysis*
  • Dust / analysis
  • Environmental Monitoring / instrumentation*
  • Environmental Monitoring / methods
  • Environmental Monitoring / standards
  • Humans
  • Inhalation Exposure / analysis*
  • Occupational Exposure / analysis*
  • Particle Size
  • Specimen Handling
  • Workplace

Substances

  • Aerosols
  • Air Pollutants, Occupational
  • Dust