3D Image Fusion to Localise Intercostal Arteries During TEVAR

EJVES Short Rep. 2017 Apr 4:35:7-10. doi: 10.1016/j.ejvssr.2017.03.001. eCollection 2017.

Abstract

Purpose: Preservation of intercostal arteries during thoracic aortic procedures reduces the risk of post-operative paraparesis. The origins of the intercostal arteries are visible on pre-operative computed tomography angiography (CTA), but rarely on intra-operative angiography. The purpose of this report is to suggest an image fusion technique for intra-operative localisation of the intercostal arteries during thoracic endovascular repair (TEVAR).

Technique: The ostia of the intercostal arteries are identified and manually marked with rings on the pre-operative CTA. The optimal distal landing site in the descending aorta is determined and marked, allowing enough length for an adequate seal and attachment without covering more intercostal arteries than necessary. After 3D/3D fusion of the pre-operative CTA with an intra-operative cone-beam CT (CBCT), the markings are overlaid on the live fluoroscopy screen for guidance. The accuracy of the overlay is confirmed with digital subtraction angiography (DSA) and the overlay is adjusted when needed. Stent graft deployment is guided by the markings. The initial experience of this technique in seven patients is presented.

Results: 3D image fusion was feasible in all cases. Follow-up CTA after 1 month revealed that all intercostal arteries planned for preservation, were patent. None of the patients developed signs of spinal cord ischaemia.

Conclusion: 3D image fusion can be used to localise the intercostal arteries during TEVAR. This may preserve some intercostal arteries and reduce the risk of post-operative spinal cord ischaemia.

Keywords: 3D image fusion; Cone-beam CT; Image guidance; Intercostal artery; Spinal cord ischaemia; TEVAR.