Utility of (18) F-FDG PET/CT and CECT in conjunction with serum CA 19-9 for detecting recurrent pancreatic adenocarcinoma

Abdom Radiol (NY). 2018 Feb;43(2):505-513. doi: 10.1007/s00261-017-1316-z.

Abstract

Purpose: The roles of different cross-sectional imaging in evaluating the recurrence of pancreatic adenocarcinoma are not well established. We evaluated the utility of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced computed tomography (CECT) in the diagnosis of recurrent pancreatic adenocarcinoma in conjunction with the tumor marker CA 19-9.

Methods: We retrospectively reviewed the records of patients who underwent CECT and FDG PET/CT along with serum CA 19-9 measurement as a follow-up or on a clinical suspicion of recurrent disease after initial surgery for pancreatic adenocarcinoma. Two observers blinded to the other imaging modality results retrospectively reviewed and interpreted the images in consensus using a three-point scale (negative, equivocal, or positive). Pathologic analysis by biopsy or further clinical and radiologic follow-up determined the true status of the suspected recurrences. The imaging results were compared with CA 19-9 levels and true disease status.

Results: Thirty-nine patients were included in the study. Thirty-three patients (85%) had proven recurrent cancer and six patients (15%) had no evidence of disease. Twenty-four patients had elevated CA 19-9 and 15 patients had normal CA 19-9. Sensitivity, specificity, and accuracy for recurrence were 90.9%, 100.0%, and 92.3% for PET/CT and 72.2%, 66.6%, and 71.7% for CECT, respectively. Sensitivity for locoregional recurrence was 94.4% for PET/CT but only 61.1% for CECT. PET/CT detected recurrence in 12 patients who had normal levels of CA 19-9. PET/CT showed lesions not visible on CECT in five (15%) patients. Although the sensitivity and specificity of PET/CT were higher than those of CECT, they were not statistically significant (p = 0.489 and p = 0.1489, respectively).

Conclusion: FDG PET/CT has a high sensitivity for pancreatic cancer recurrence. Normal CA 19-9 does not necessarily exclude these recurrences. FDG PET/CT is useful when CECT is equivocal and can detect recurrence in patients with normal CA 19-9.

Keywords: CECT; Ca 19-9; PET/CT; Pancreatic cancer; Recurrence.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Adenocarcinoma / diagnostic imaging*
  • Adenocarcinoma / pathology*
  • Aged
  • Biomarkers, Tumor / blood*
  • CA-19-9 Antigen / blood*
  • Contrast Media
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local / diagnostic imaging*
  • Neoplasm Recurrence, Local / pathology*
  • Pancreatic Neoplasms / diagnostic imaging*
  • Pancreatic Neoplasms / pathology*
  • Positron Emission Tomography Computed Tomography / methods*
  • Radiopharmaceuticals
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*
  • Triiodobenzoic Acids

Substances

  • Biomarkers, Tumor
  • CA-19-9 Antigen
  • Contrast Media
  • Radiopharmaceuticals
  • Triiodobenzoic Acids
  • Fluorodeoxyglucose F18
  • ioversol