Abstract

Electrical injuries make up a relatively small portion of burn injuries. Safety measures in place on domestic electricity supply have reduced the occurrence of high voltage electrical injuries. We present the case of a young man who sustained a high voltage electrical injury on all four limbs. Early fasciotomy was performed on both his hands and forearms. Despite early compartment release, the left upper limb deteriorated and required amputation. In this article we discuss the indications, outcomes and complications of early fasciotomy.

Les atteintes électrothermiques représentent une faible proportion des brûlures. Les brûlures par haut voltage à domicile ont vu leur incidence diminuer grâce aux protections automatiques. Nous présentons le cas d’un jeune homme ayant subi des brûlures par haut voltage au niveau des 4 membres. Des aponévrotomies ont été réalisées précocement au niveau des avant bras et des mains. Malgré la prise en charge rapide du syndrome compartimental, le membre supérieur gauche a dû être amputé. Nous discutons ici des indications, des complications et de l’intérêt des aponévrotomies précoces.

Keywords: early fasciotomy; electrical injury; high voltage; limb salvage.