One-year clinical and computed tomography follow-up after implantation of bioresorbable vascular scaffolds in patients with coronary chronic total occlusions

Catheter Cardiovasc Interv. 2018 Sep 1;92(3):488-496. doi: 10.1002/ccd.27390. Epub 2017 Oct 25.

Abstract

Objectives: To assess the safety and efficacy of everolimus-eluting bioresorbable scaffolds (BRS) in the treatment of chronic total occlusions (CTO) using noninvasive multislice computed tomography (MSCT) angiography at one-year follow-up.

Background: Current evidence regarding the safety and efficacy of BRS for the percutaneous treatment of CTO is limited.

Methods: Between September 2013 and January 2016, patients who received one or more ABSORB BRSs were included at three centers. MSCT (including quantitative analysis) and clinical follow-up were performed at one year.

Results: Forty-one CTO patients were included. Mean age was 60 ± 11 years and the majority was male (83%). Average Japanese CTO (J-CTO) score was 0.9 ± 0.9. Seventy-one BRS were implanted in total with, on average, 1.7 ± 0.8 scaffolds/patient, and a total length of 43 ± 20 mm and diameter of 3.1 ± 0.4 mm. One noncardiac death took place. MSCT angiography was performed in 34 (83%) patients: all scaffolds were patent, except in one patient, in whom a patent target vessel was present on subsequent diagnostic angiography. MSCT quality was sufficient for quantitative analyses in 27 patients (46 scaffolds): median reference versus scaffold minimal lumen diameter and minimal lumen area were measured, and showed a small difference of 0.1 mm (-0.2-0.4) (lumen diameter stenosis = 3.0%) and 0.5 mm2 (-1.0-2.0) (lumen area stenosis = 4.2%).

Conclusions: The low number of events and high patency rate at 1 year are encouraging the further use of the ABSORB scaffold for CTOs with low J-CTO score. Noninvasive MSCT angiography is a valid tool to assess scaffold patency, although its image resolution limits the use for quantitative measurements.

Keywords: coronary artery disease; imaging-multidetector CT; percutaneous coronary intervention; stent-bioabsorbable.

Publication types

  • Multicenter Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Cardiovascular Agents / administration & dosage
  • Chronic Disease
  • Coated Materials, Biocompatible
  • Computed Tomography Angiography / methods*
  • Coronary Angiography / methods*
  • Coronary Occlusion / diagnostic imaging*
  • Coronary Occlusion / physiopathology
  • Coronary Occlusion / therapy*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology
  • Coronary Restenosis / physiopathology
  • Coronary Vessels / diagnostic imaging*
  • Coronary Vessels / physiopathology
  • Europe
  • Everolimus / administration & dosage
  • Female
  • Humans
  • Male
  • Middle Aged
  • Multidetector Computed Tomography / methods*
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Reproducibility of Results
  • Time Factors
  • Treatment Outcome
  • Vascular Patency

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Everolimus