Relative merits and limiting factors for x-ray and electron microscopy of thick, hydrated organic materials
Erratum in
-
Corrigendum to: "Relative merits and limiting factors for x-ray and electron microscopy of thick, hydrated organic materials" [Ultramicroscopy 184 (2018) 293-309].Ultramicroscopy. 2020 Sep;216:113013. doi: 10.1016/j.ultramic.2020.113013. Epub 2020 May 4. Ultramicroscopy. 2020. PMID: 32554165 Free PMC article.
Abstract
Electron and x-ray microscopes allow one to image the entire, unlabeled structure of hydrated materials at a resolution well beyond what visible light microscopes can achieve. However, both approaches involve ionizing radiation, so that radiation damage must be considered as one of the limits to imaging. Drawing upon earlier work, we describe here a unified approach to estimating the image contrast (and thus the required exposure and corresponding radiation dose) in both x-ray and electron microscopy. This approach accounts for factors such as plural and inelastic scattering, and (in electron microscopy) the use of energy filters to obtain so-called "zero loss" images. As expected, it shows that electron microscopy offers lower dose for specimens thinner than about 1 µm (such as for studies of macromolecules, viruses, bacteria and archaebacteria, and thin sectioned material), while x-ray microscopy offers superior characteristics for imaging thicker specimen such as whole eukaryotic cells, thick-sectioned tissues, and organs. The required radiation dose scales strongly as a function of the desired spatial resolution, allowing one to understand the limits of live and frozen hydrated specimen imaging. Finally, we consider the factors limiting x-ray microscopy of thicker materials, suggesting that specimens as thick as a whole mouse brain can be imaged with x-ray microscopes without significant image degradation should appropriate image reconstruction methods be identified.
Keywords: Electron; Radiation damage; Thick specimen; X-Ray.
Copyright © 2017 Elsevier B.V. All rights reserved.
Figures
Similar articles
-
Advantages of intermediate X-ray energies in Zernike phase contrast X-ray microscopy.Biotechnol Adv. 2013 May-Jun;31(3):387-92. doi: 10.1016/j.biotechadv.2012.04.001. Epub 2012 Apr 13. Biotechnol Adv. 2013. PMID: 22521962
-
Soft x-ray microscopy.Trends Cell Biol. 1999 Feb;9(2):44-7. doi: 10.1016/s0962-8924(98)01424-x. Trends Cell Biol. 1999. PMID: 10087616 Review.
-
Imaging Drosophila brain by combining cryo-soft X-ray microscopy of thick vitreous sections and cryo-electron microscopy of ultrathin vitreous sections.J Struct Biol. 2014 Nov;188(2):177-82. doi: 10.1016/j.jsb.2014.09.012. Epub 2014 Oct 6. J Struct Biol. 2014. PMID: 25301679
-
Soft X-ray contact microscopy of biological materials.Electron Microsc Rev. 1991;4(2):269-92. doi: 10.1016/0892-0354(91)90006-x. Electron Microsc Rev. 1991. PMID: 1932584 Review.
-
X-ray ptychographic and fluorescence microscopy of frozen-hydrated cells using continuous scanning.Sci Rep. 2017 Mar 27;7(1):445. doi: 10.1038/s41598-017-00569-y. Sci Rep. 2017. PMID: 28348401 Free PMC article.
Cited by
-
Computational models of amorphous ice for accurate simulation of cryo-EM images of biological samples.Ultramicroscopy. 2024 Feb;256:113882. doi: 10.1016/j.ultramic.2023.113882. Epub 2023 Nov 4. Ultramicroscopy. 2024. PMID: 37979542 Free PMC article.
-
Multivariate hyperspectral data analytics across length scales to probe compositional, phase, and strain heterogeneities in electrode materials.Patterns (N Y). 2022 Nov 17;3(12):100634. doi: 10.1016/j.patter.2022.100634. eCollection 2022 Dec 9. Patterns (N Y). 2022. PMID: 36569543 Free PMC article.
-
In situ X-ray-assisted electron microscopy staining for large biological samples.Elife. 2022 Oct 20;11:e72147. doi: 10.7554/eLife.72147. Elife. 2022. PMID: 36263931 Free PMC article.
-
Sample Preparation and Warping Accuracy for Correlative Multimodal Imaging in the Mouse Olfactory Bulb Using 2-Photon, Synchrotron X-Ray and Volume Electron Microscopy.Front Cell Dev Biol. 2022 Jun 8;10:880696. doi: 10.3389/fcell.2022.880696. eCollection 2022. Front Cell Dev Biol. 2022. PMID: 35756997 Free PMC article.
-
Functional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron microtomography and volume electron microscopy.Nat Commun. 2022 May 25;13(1):2923. doi: 10.1038/s41467-022-30199-6. Nat Commun. 2022. PMID: 35614048 Free PMC article.
References
-
- Gustafsson MG. Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy. Journal of Microscopy. 2000;198(2):82–87. - PubMed
-
- Burton M. General discussion. Discussions of the Faraday Society. 1952;12:317–318.
-
- Chapiro A. Radiation Chemistry of Polymeric Systems. Interscience Publishers; 1962.
-
- Haas DJ, Rossmann MG. Crystallographic studies on lactate dehydrogenase at −75°C. Acta Crystallographica B. 1970;26(7):998–1004. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials