DETERMINATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS IN COMPUTED TOMOGRAPHY EXAMINATIONS OF IRAN BY A NEW QUALITY CONTROL-BASED DOSE SURVEY METHOD

Radiat Prot Dosimetry. 2018 May 1;179(3):206-215. doi: 10.1093/rpd/ncx252.

Abstract

National diagnostic reference levels (NDRLs) of Iran were determined for the four most common CT examinations including head, sinus, chest and abdomen/pelvis. A new 'quality control (QC)-based dose survey method', as developed by us, was applied to 157 CT scanners in Iran (2014-15) with different slice classes, models and geographic spread across the country. The NDRLs for head, sinus, chest and abdomen/pelvis examinations are 58, 29, 12 and 14 mGy for CTDIVol and 750, 300, 300 and 650 mGy.cm for DLP, respectively. The 'QC-based dose survey method' was further proven that it is a simple, accurate and practical method for a time and cost-effective NDRLs determination. One effective approach for optimization of the CT examination protocols at the national level is the provision of an adequate standardized training of the radiologists, technicians and medical physicists on the patient radiation protection principles and implementation of the DRL concept in clinical practices.

MeSH terms

  • Head / radiation effects*
  • Humans
  • Iran
  • Pelvis / radiation effects*
  • Phantoms, Imaging*
  • Quality Control*
  • Radiation Dosage
  • Radiation Protection
  • Radiography, Abdominal / standards*
  • Radiography, Thoracic / standards*
  • Reference Standards
  • Reference Values
  • Sinoatrial Node / radiation effects
  • Surveys and Questionnaires
  • Tomography Scanners, X-Ray Computed / standards*
  • Tomography, X-Ray Computed / methods
  • Tomography, X-Ray Computed / standards*