Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support
- PMID: 29164425
- DOI: 10.1007/s10047-017-1006-1
Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support
Abstract
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90°, 0-180°), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients' age was 38 ± 11 years. Support duration was 686 ± 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 ± 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 ± 9°) than in those with 1.5 or greater (94 ± 15°, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.
Keywords: Aortic valve regurgitation; Continuous-flow; Heart failure; Left ventricular assist device.
Similar articles
-
The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.J Artif Organs. 2018 Dec;21(4):399-404. doi: 10.1007/s10047-018-1064-z. Epub 2018 Jul 23. J Artif Organs. 2018. PMID: 30039455
-
Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design.J Thorac Cardiovasc Surg. 2015 Sep;150(3):696-704. doi: 10.1016/j.jtcvs.2015.05.034. Epub 2015 May 15. J Thorac Cardiovasc Surg. 2015. PMID: 26092505
-
De novo aortic regurgitation after continuous-flow left ventricular assist device implantation.Ann Thorac Surg. 2014 Sep;98(3):850-7. doi: 10.1016/j.athoracsur.2014.05.030. Epub 2014 Jul 25. Ann Thorac Surg. 2014. PMID: 25069685
-
Aortic regurgitation in patients with a left ventricular assist device: A contemporary review.J Heart Lung Transplant. 2018 Nov;37(11):1289-1297. doi: 10.1016/j.healun.2018.07.002. Epub 2018 Sep 7. J Heart Lung Transplant. 2018. PMID: 30197211 Review.
-
De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation.Ann Thorac Surg. 2017 Aug;104(2):704-711. doi: 10.1016/j.athoracsur.2017.01.114. Epub 2017 May 6. Ann Thorac Surg. 2017. PMID: 28483150 Review.
Cited by
-
The Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency.Biomimetics (Basel). 2023 Oct 1;8(6):465. doi: 10.3390/biomimetics8060465. Biomimetics (Basel). 2023. PMID: 37887596 Free PMC article.
-
Considerations of valvular heart disease in children with ventricular assist devices.Front Cardiovasc Med. 2023 Mar 22;10:1056663. doi: 10.3389/fcvm.2023.1056663. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37034354 Free PMC article. Review.
-
Aortic valve disorders and left ventricular assist devices.Front Cardiovasc Med. 2023 Feb 23;10:1098348. doi: 10.3389/fcvm.2023.1098348. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 36910539 Free PMC article. Review.
-
Factors influencing the functional status of aortic valve in ovine models supported by continuous-flow left ventricular assist device.Artif Organs. 2022 Jul;46(7):1334-1345. doi: 10.1111/aor.14207. Epub 2022 Mar 3. Artif Organs. 2022. PMID: 35167127 Free PMC article.
-
The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support.J Artif Organs. 2018 Dec;21(4):399-404. doi: 10.1007/s10047-018-1064-z. Epub 2018 Jul 23. J Artif Organs. 2018. PMID: 30039455
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials