. 2017 Sep 21:15:314-319.
doi: 10.1016/j.dib.2017.09.033. eCollection 2017 Dec.

EEG/EOG/EMG data from a cross sectional study on psychophysiological insomnia and normal sleep subjects

Affiliations

EEG/EOG/EMG data from a cross sectional study on psychophysiological insomnia and normal sleep subjects

Mohammad Rezaei et al. Data Brief. .

Abstract

The data presented here had been originally collected for a research project entitled 'Sleep EEG spectral analysis in psychophysiological insomnia and normal sleep subjects'. This article describes the data of 11 subjects, referred to Sleep Disorders Research Center (SDRC) in Kermanshah, Iran. The data includes 14 EEG, 6 EOG, and 3 EMG channels, with a sampling ratio of 256 Hz. It includes power spectral features in segments of 30 s for each channel, and nonlinear analysis parameter. Also, the complete demographic and polysomnography specifications are attached.

Keywords: EEG; Insomnia; Psychophysiological; Sleep dataset.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Electrode montage corresponding to the international 10–20: Sites included frontal (F3, F4), central (C3, C4), and occipital (01, 02) placements of the International 10–20 System.
Fig. 2
Fig. 2
6 EEG channels sampled at 256 Hz using SOMNOscreen PSG (SOMNOscreen TM plus PSG+, SOMNOmedics GmbH, Germany). This shows the voltage in microvolts on each channel referenced to the left or right earlobe (A1, A2) over a 4 s window.
Fig. 3
Fig. 3
A typical Poincare plot. The horizontal axes demonstrate the illustrating the statics result at a specific epoch (x(k)) and the vertical axis illustrating the statics result after a specified epoch delay (x(k+1)). An ellipse is fitted to the data points and the Poincare plot descriptors are measured by estimating the SD perpendicular to the diametric line was defined as SD1, and the SD along the diametric line was defined as SD2 and ratio of the SD1/SD2 of the fitted ellipse.

Similar articles

Cited by

References

    1. M. Rezaei, H. Mohammadi, H. Khazaie, EEG/EOG/EMG data from a cross sectional study on psychophysiological insomnia and normal sleep subjects, Mendeley Data, v1, 2017. 〈http://dx.doi.org/10.17632/3hx58k232n.1〉 (DOI is reserved but not active). - DOI - PMC - PubMed
    1. Mollayeva T., Thurairajah P., Burton K., Mollayeva S., Shapiro C.M., Colantonio A. The Pittsburgh Sleep Quality Index as a screening tool for sleep dysfunction in clinical and non-clinical samples: a systematic review and meta-analysis. Sleep Med. Rev. 2016;25:52–73. - PubMed
    1. Buysse D.J., Reynolds C.F., Monk T.H., Berman S.R., Kupfer D.J. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989;28:193–213. - PubMed
    1. Rezaei M., Amiri M., Mohajeri P., Rezaei M. A new algorithm for lane detection and tracking on pulsed field gel electrophoresis images. Chemom. Intell. Lab. Syst. 2016;157:1–6.
    1. M. Frigo, S.G. Johnson, FFTW: an adaptive software architecture for the FFT, in: Proceedings of the International Conference on Acoustics, Speech, and Signal Processing, vol. 3, 1998, pp. 1381–1384.

LinkOut - more resources