Flip-angle based ratiometric approach for pulsed CEST-MRI pH imaging

J Magn Reson. 2018 Feb:287:1-9. doi: 10.1016/j.jmr.2017.12.007. Epub 2017 Dec 11.

Abstract

Several molecules have been exploited for developing MRI pH sensors based on the chemical exchange saturation transfer (CEST) technique. A ratiometric approach, based on the saturation of two exchanging pools at the same saturation power, or by varying the saturation power levels on the same pool, is usually needed to rule out the concentration term from the pH measurement. However, all these methods have been demonstrated by using a continuous wave saturation scheme that limits its translation to clinical scanners. This study shows a new ratiometric CEST-MRI pH-mapping approach based on a pulsed CEST saturation scheme for a radiographic contrast agent (iodixanol) possessing a single chemical exchange site. This approach is based on the ratio of the CEST contrast effects at two different flip angles combinations (180°/360° and 180°/720°), keeping constant the mean irradiation RF power (Bavg power). The proposed ratiometric approach index is concentration independent and it showed good pH sensitivity and accuracy in the physiological range between 6.0 and 7.4.

Keywords: CEST; Contrast media; Iodinated contrast media; MRI; Pulsed-CEST; Radiographic agents; Train pulses; pH.