Substrate utilization kinetic model for biological treatment process

Biotechnol Bioeng. 1980 Oct;22(10):2081-2095. doi: 10.1002/bit.260221008.

Abstract

The applicability of Contois' kinetic equation to aerobic and anaerobic treatments of organic wastes is investigated. A refractory coefficient to account for the nonbiodegradable portion of the organic substrates in the digester is incorporated into the kinetic equation. The kinetic equation is applied to the data for aerobic digestions of organic substrates and for anaerobic treatment of dairy wastes. They all show a very good fit of the kinetic equation to the data. Furthermore, the kinetic parameters and the refractory coefficients are shown to be independent of influent organic substrate concentration. This study confirms previous reports that the effluent quality of biological treatment systems for organic wastes depends on influent organic waste concentration. The effect of temperature on the kinetic parameters and the refractory coefficient for anaerobic treatment of sewage sludge are studied. It shows that the kinetic parameters vary with temperature, while the refractory coefficient remains fairly constant. Equations to predict biodegradable treatment efficiency and volumetric substrate utilization rate are also briefly discussed.