A novel electrochemical immunosensor based on PG for early screening of depression markers-heat shock protein 70

Biosens Bioelectron. 2018 Jul 15:111:34-40. doi: 10.1016/j.bios.2018.03.049. Epub 2018 Mar 23.

Abstract

In this study, a novel electrochemical immunosensor for early screening of depression markers-heat shock protein 70 (HSP70) was successfully developed based on the porous graphene (PG) with huge specific surface area and excellent structure. Benefiting from the strong adsorption and good bioactivity of PG which was initially prepared via a simple pyrolysis process, a variety of heat shock protein70 (HSP70) can be firmly loaded on the PG to construct the basic electrode (HSP70/PG/GCE),which was characterized by the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), respectively. Due to the HSP70 fixed on the surface of basic electrode and the HSP70 in the samples can competitively combine with the horseradish peroxidase labeled human HSP 70 antibody (HRP-Strept-Biotin-Ab). As a result, it presented a negative correlation between the concentration of HSP70 in samples and the detection signal of the proposed electrochemical immunosensor (HRP-Strept-Biotin-Ab-HSP70/PG/GCE) in the test liquid. The application of PG with excellent electrical conductivity in construction of immunosensor remarkably improved the sensitivity of the immunosensor for detection of HSP70. The proposed immunosensor demonstrated a wide linear range of 0.0448 ~ 100 ng/mL with a low detection limit of 0.02 ng/mL at 3σ. Moreover, the proposed immunosensor could be applied for the sensitive and efficient detection of HSP70 in real samples with good precision, acceptable stability, reproducibility and satisfactory results. Therefore, the HSP70 immunosensor provides a novel and convenient method for early clinical screening of depression markers-heat shock protein 70.

Keywords: Electrochemical immunosensor; Heat shock protein70 (HSP70); Porous grapheme (PG).

Publication types

  • Evaluation Study

MeSH terms

  • Antibodies, Immobilized / chemistry*
  • Biomarkers / blood
  • Biosensing Techniques / instrumentation
  • Biosensing Techniques / methods*
  • Depression / blood*
  • Electrochemical Techniques / instrumentation
  • Electrochemical Techniques / methods
  • Equipment Design
  • Graphite / chemistry*
  • HSP70 Heat-Shock Proteins / blood*
  • Humans
  • Immunoassay / instrumentation
  • Immunoassay / methods*
  • Limit of Detection
  • Porosity
  • Reproducibility of Results

Substances

  • Antibodies, Immobilized
  • Biomarkers
  • HSP70 Heat-Shock Proteins
  • Graphite