Comparison of High Resolution T2W and Gd-T1W of MRI Internal Acoustic Canal in Sensorineural Hearing Loss

J Med Assoc Thai. 2016 Nov;99(11):1245-9.

Abstract

Objective: To evaluate the concordance of high resolution T2-weighted (HR-T2W) and Gd-T1W for mass detection in internal acoustic canal (IAC) or cochlear in sensorineural hearing loss (SNHL).

Material and method: The retrospective study of patients with SNHL undergoing magnetic resonance imaging (MRI) IAC protocol was performed. HR-T2W and Gd-T1W were separately reviewed for any mass in IAC or cochlear.

Results: One hundred eight cases were available for evaluation with 43 males and 65 females (mean age of 56.04 years old; range 15 to 86 years old). Symptoms of SNHL on right side were 39 cases (36.1%), left side 39 cases (36.1%), both sides 15 cases (13.9%), and asymmetric SNHL 15 cases (13.9%). Twenty two (20.4%) cases had mass in IAC and/or cochlear demonstrated on both HR-T2W and Gd-T1W. No discrepancy of abnormality detection between both pulse sequences was found.

Conclusion: HR-T2W was as accurate as Gd-T1W in detecting mass in IAC and cochlear in patients with SNHL. Screening with HR-T2W could be used with confidence and might be reasonable to reducing cost of the MRI study in appropriate setting of patients presenting with SNHL.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Ear, Inner / diagnostic imaging*
  • Female
  • Hearing Loss, Sensorineural / diagnostic imaging*
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Retrospective Studies
  • Young Adult