A Modified String Technique for Atraumatic Ring Removal

J Emerg Med. 2018 Aug;55(2):240-243. doi: 10.1016/j.jemermed.2018.05.022. Epub 2018 Jun 19.

Abstract

Background: We describe a modified string technique for ring removal from an edematous finger, a critical step in the initial treatment of a patient with upper-extremity trauma.

Technique: This technique involves multiple sutures looped around the ring to provide differential tension on the ring as it is advanced distally over a lubricated digit. With the use of an assistant, the ring can be advanced in caterpillar fashion without sliding back proximal when the direct pressure is released as a result of edema.

Conclusions: This multisuture technique adds to the armamentarium of methods for ring removal in the setting of upper-extremity trauma without reverting to alternate techniques for cutting or shattering the ring.

Keywords: edematous finger; hand; upper-extremity trauma.

MeSH terms

  • Device Removal / instrumentation*
  • Device Removal / methods*
  • Device Removal / standards
  • Edema / complications
  • Humans
  • Jewelry / adverse effects*
  • Sutures*