The effect of follower load on the intersegmental coupled motion characteristics of the human thoracic spine: An in vitro study using entire rib cage specimens
- PMID: 30031651
- DOI: 10.1016/j.jbiomech.2018.06.025
The effect of follower load on the intersegmental coupled motion characteristics of the human thoracic spine: An in vitro study using entire rib cage specimens
Abstract
The mechanical coupling behaviour of the thoracic spine is still not fully understood. For the validation of numerical models of the thoracic spine, however, the coupled motions within the single spinal segments are of importance to achieve high model accuracy. In the present study, eight fresh frozen human thoracic spinal specimens (C7-L1, mean age 54 ± 6 years) including the intact rib cage were loaded with pure bending moments of 5 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) with and without a follower load of 400 N. During loading, the relative motions of each vertebra were monitored. Follower load decreased the overall ROM (T1-T12) significantly (p < 0.01) in all primary motion directions (extension: -46%, left LB: -72%, right LB: -72%, left AR: -26%, right AR: -26%) except flexion (-36%). Substantial coupled motion was found in lateral bending with ipsilateral axial rotation, which increased after a follower load was applied, leading to a dominant axial rotation during primary lateral bending, while all other coupled motions in the different motion directions were reduced under follower load. On the monosegmental level, the follower load especially reduced the ROM of the upper thoracic spine from T1-T2 to T4-T5 in all motion directions and the ROM of the lower thoracic spine from T9-T10 to T11-T12 in primary lateral bending. The facet joints, intervertebral disc morphologies, and the sagittal curvature presumably affect the thoracic spinal coupled motions depending on axial compressive preloading. Using these results, the validation of numerical models can be performed more accurately.
Keywords: Coupled motions; Follower load; In vitro study; Rib cage; Thoracic spine.
Copyright © 2018 Elsevier Ltd. All rights reserved.
Similar articles
-
Effect of follower load on motion and stiffness of the human thoracic spine with intact rib cage.J Biomech. 2016 Oct 3;49(14):3252-3259. doi: 10.1016/j.jbiomech.2016.08.003. Epub 2016 Aug 8. J Biomech. 2016. PMID: 27545081 Free PMC article.
-
The rib cage stiffens the thoracic spine in a cadaveric model with body weight load under dynamic moments.J Mech Behav Biomed Mater. 2018 Aug;84:258-264. doi: 10.1016/j.jmbbm.2018.05.019. Epub 2018 May 16. J Mech Behav Biomed Mater. 2018. PMID: 29852313 Free PMC article.
-
The rib cage reduces intervertebral disc pressures in cadaveric thoracic spines by sharing loading under applied dynamic moments.J Biomech. 2018 Mar 21;70:262-266. doi: 10.1016/j.jbiomech.2017.10.005. Epub 2017 Oct 12. J Biomech. 2018. PMID: 29106896 Free PMC article.
-
Challenging the Conventional Standard for Thoracic Spine Range of Motion: A Systematic Review.JBJS Rev. 2016 Apr 5;4(4):e51-e511. doi: 10.2106/JBJS.RVW.O.00048. JBJS Rev. 2016. PMID: 27487429 Review.
-
Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.J Biomech. 2020 Feb 13;100:109579. doi: 10.1016/j.jbiomech.2019.109579. Epub 2019 Dec 16. J Biomech. 2020. PMID: 31911050 Free PMC article. Review.
Cited by
-
In vitro coupled motions of the whole human thoracic and lumbar spine with rib cage.JOR Spine. 2023 May 4;6(3):e1257. doi: 10.1002/jsp2.1257. eCollection 2023 Sep. JOR Spine. 2023. PMID: 37780824 Free PMC article.
-
Classification of thoracic spine fractures: the four-column theory.Int Orthop. 2023 Dec;47(12):2907-2915. doi: 10.1007/s00264-023-05778-x. Epub 2023 Mar 21. Int Orthop. 2023. PMID: 36943457 Free PMC article. Review.
-
How Does the Rib Cage Affect the Biomechanical Properties of the Thoracic Spine? A Systematic Literature Review.Front Bioeng Biotechnol. 2022 Jun 15;10:904539. doi: 10.3389/fbioe.2022.904539. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 35782518 Free PMC article.
-
In vitro Analysis of the Intradiscal Pressure of the Thoracic Spine.Front Bioeng Biotechnol. 2020 Jun 17;8:614. doi: 10.3389/fbioe.2020.00614. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 32626699 Free PMC article.
-
Thoracic Spinal Stability and Motion Behavior Are Affected by the Length of Posterior Instrumentation After Vertebral Body Replacement, but Not by the Surgical Approach Type: An in vitro Study With Entire Rib Cage Specimens.Front Bioeng Biotechnol. 2020 Jun 9;8:572. doi: 10.3389/fbioe.2020.00572. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 32582680 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous