A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children

Nucl Med Mol Imaging. 2018 Aug;52(4):293-302. doi: 10.1007/s13139-018-0529-6. Epub 2018 Jun 28.

Abstract

Purpose: Among the different methods of measuring glomerular filtration rate (GFR) using 51Cr-ethylenediaminetetraacetic acid clearance, the two-plasma-sample method (TPSM) is widely used, and highly accurate. The single-plasma-sample method (SPSM) is occasionally used for simplicity, at the expense of accuracy. Our aims were (1) to investigate the correlation and (2) to compare the accuracy of six known SPSMs in pediatric patients in reference to TPSM.

Methods: We retrospectively reviewed 122 pediatric cases (65 boys, age 7.3 ± 4.6 years) and analyzed 307 GFR measurements. SPSMs included Groth and Aasted at 120 min, Ham at 120 min, Christensen and Groth at 120 and 240 min, and Jacobsson at 120 and 240 min. Reference GFR (GFRref) was defined using TPSM GFR corrected by the Jodal and Brochner-Mortensen equation. GFRref < 30 mL min-1 1.73 m-2 were excluded. The standard error of the estimate (SEE) and the number of cases with differences > 10% (N10%) were used to evaluate accuracy.

Results: SPSMs generally correlated well with GFRref (r = 0.92~0.99) and were relatively accurate (SEE = 9.21~15.60). Groth and Aasted showed the smallest SEE, while Jacobsson at 240 min showed the smallest N10% for all GFRref ranges. As for the decreased GFRref, Ham was most accurate followed by Jacobsson at 240 min.

Conclusions: Jacobsson at 240 min provided good accuracy in all GFRref ranges and was well correlated with TPSM. Jacobsson at 240 min might be the most appropriate method to substitute for TPSM in pediatric patients. Ham could be an alternative in patients with impaired renal function.

Keywords: 51Cr-EDTA; Children; Glomerular filtration rate; Single plasma sample method.