. 2018 Aug 13;8(1):12051.
doi: 10.1038/s41598-018-30334-8.

Iterative and Discrete Reconstruction in the Evaluation of the Rabbit Model of Osteoarthritis

Affiliations
Free PMC article

Iterative and Discrete Reconstruction in the Evaluation of the Rabbit Model of Osteoarthritis

Juuso H Ketola et al. Sci Rep. .
Free PMC article

Abstract

Micro-computed tomography (µCT) is a standard method for bone morphometric evaluation. However, the scan time can be long and the radiation dose during the scan may have adverse effects on test subjects, therefore both of them should be minimized. This could be achieved by applying iterative reconstruction (IR) on sparse projection data, as IR is capable of producing reconstructions of sufficient image quality with less projection data than the traditional algorithm requires. In this work, the performance of three IR algorithms was assessed for quantitative bone imaging from low-resolution data in the evaluation of the rabbit model of osteoarthritis. Subchondral bone images were reconstructed with a conjugate gradient least squares algorithm, a total variation regularization scheme, and a discrete algebraic reconstruction technique to obtain quantitative bone morphometry, and the results obtained in this manner were compared with those obtained from the reference reconstruction. Our approaches were sufficient to identify changes in bone structure in early osteoarthritis, and these changes were preserved even when minimal data were provided for the reconstruction. Thus, our results suggest that IR algorithms give reliable performance with sparse projection data, thereby recommending them for use in µCT studies where time and radiation exposure are preferably minimized.

Conflict of interest statement

The authors declare no competing interests.

Figures

Figure 1
Figure 1
Example images of reconstructed data, shown as one 80 × 160 pixel image from the 80 × 80 × 160 voxel volume of interest. FDK = Feldkamp, David and Kress algorithm, CGLS = conjugate gradient least squares algorithm, TV = total variation regularization and DART = discrete algebraic reconstruction technique. The number of projection images used in reconstruction is denoted by n.
Figure 2
Figure 2
The binarized slice images corresponding to the data in Fig. 1. FDK = Feldkamp, David and Kress algorithm, CGLS = conjugate gradient least squares algorithm, TV = total variation regularization and DART = discrete algebraic reconstruction technique. The number of projection images used in reconstruction is denoted by n.
Figure 3
Figure 3
The mean relative error of the used iterative algorithms with regards to reference data in quantitative bone morphometry analysis. The number below each bar trio corresponds to the number of used projection images. The bar height indicates the mean and the error bars indicate the standard deviation of the data. The analyzed morphometric parameters were BV/TV = bone volume fraction, Pl.Th = plate thickness, EF = ellipsoid factor, Tb.S = trabecular separation, Tb.Th = trabecular thickness and Tb.N = trabecular number. FDK = Feldkamp, David and Kress algorithm, CGLS = conjugate gradient least squares algorithm, TV = total variation regularization and DART = discrete algebraic reconstruction technique.
Figure 4
Figure 4
Contrast-to-noise ratio (CNR) as a function of used projection images. For iterative algorithms, the bar height indicates the mean and the error bars indicate the standard deviation in the data. For FDK, the continuous line refers to the mean (reference level) and the dashed lines indicate the standard deviation in the data. FDK = Feldkamp, David and Kress algorithm, CGLS = conjugate gradient least squares algorithm, TV = total variation regularization and DART = discrete algebraic reconstruction technique.

Similar articles

See all similar articles

References

    1. Boutroy S, Bouxsein ML, Munoz F, Delmas PD. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J. Clin. Endocrinol. Metab. 2005;90:6508–15. doi: 10.1210/jc.2005-1258. - DOI - PubMed
    1. Holdsworth DW, Thornton MM. Micro-CT in small animal and specimen imaging. Trends Biotechnol. 2002;20:34–39. doi: 10.1016/S0167-7799(02)02004-8. - DOI
    1. Schambach SJ, Bag S, Schilling L, Groden C, Brockmann MA. Application of micro-CT in small animal imaging. Methods. 2010;50:2–13. doi: 10.1016/j.ymeth.2009.08.007. - DOI - PubMed
    1. Boas FE, Fleischmann D. CT artifacts: causes and reduction techniques. Imaging Med. 2012;4:229–240. doi: 10.2217/iim.12.13. - DOI
    1. Schulze R, et al. Artefacts in CBCT: A review. Dentomaxillofacial Radiol. 2011;40:265–273. doi: 10.1259/dmfr/30642039. - DOI - PMC - PubMed

Publication types

MeSH terms

Feedback